SAP ABAP Class IWCI_WDR_OVS (Web Dynpro Interface COMPONENTCONTROLLER)
Properties
Class | IWCI_WDR_OVS | |
Short Description | Web Dynpro Interface COMPONENTCONTROLLER | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 80 | Web Dynpro Runtime Object |
Package | ||
Created | 20040802 | SAP |
Last change | 20140121 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class IWCI_WDR_OVS has no forward declaration.
Interfaces
Class IWCI_WDR_OVS has no interface implemented.
Friends
Class IWCI_WDR_OVS has no friend class.
Attributes
Class IWCI_WDR_OVS has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | 20040802 | |
2 | ![]() |
Instance method | Public | Method | 20040930 | |
3 | ![]() |
Instance method | Public | Method | 20040930 | |
4 | ![]() |
Instance method | Public | Method | 20040802 |
Events
Class IWCI_WDR_OVS has no event.
Types
Class IWCI_WDR_OVS has no local type.
Method Signatures
Method INIT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
COMMAND_LISTENER | Call by reference | Object reference (TYPE REF TO) | IF_WDR_OVS_LISTENER | 20040803 |
Method INIT on class IWCI_WDR_OVS has no exception.
Method SET_INPUT_STRUCTURE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
GROUP_HEADER | Call by reference | Type reference (TYPE) | STRING | 20041001 | |||
2 | ![]() |
INPUT | Call by reference | Type reference (TYPE) | DATA | 20040930 | |||
3 | ![]() |
LABEL_TEXTS | Call by reference | Type reference (TYPE) | WDR_NAME_VALUE_LIST | 20041001 | |||
4 | ![]() |
WINDOW_TITLE | Call by reference | Type reference (TYPE) | STRING | 20041001 |
Method SET_INPUT_STRUCTURE on class IWCI_WDR_OVS has no exception.
Method SET_OUTPUT_TABLE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
OUTPUT | Call by reference | Type reference (TYPE) | ANY TABLE | 20040930 | |||
2 | ![]() |
TABLE_HEADER | Call by reference | Type reference (TYPE) | STRING | 20041001 |
Method SET_OUTPUT_TABLE on class IWCI_WDR_OVS has no exception.
Method WD_GET_API Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RESULT | Value transfer | Object reference (TYPE REF TO) | IF_WD_CONTROLLER | 20040802 |
Method WD_GET_API on class IWCI_WDR_OVS has no exception.
History
Last changed by/on | SAP | 20140121 |
SAP Release Created in |