SAP ABAP Class IWCI_FPM_BICS_GRID_DIALOG (WebDynpro Interface COMPONENTCONTROLLER)
Properties
Class | IWCI_FPM_BICS_GRID_DIALOG | |
Short Description | WebDynpro Interface COMPONENTCONTROLLER | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 80 | Web Dynpro Runtime Object |
Package | ||
Created | 20130918 | SAP |
Last change | 20140121 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class IWCI_FPM_BICS_GRID_DIALOG has no forward declaration.
Interfaces
Class IWCI_FPM_BICS_GRID_DIALOG has no interface implemented.
Friends
Class IWCI_FPM_BICS_GRID_DIALOG has no friend class.
Attributes
Class IWCI_FPM_BICS_GRID_DIALOG has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | OPEN_FILTER_DIALOG | Instance method | Public | Method | 20130918 | |
2 | OPEN_HIERSEL_DIALOG | Instance method | Public | Method | 20130918 | |
3 | OPEN_MEASURE_DIALOG | Instance method | Public | Method | 20130918 | |
4 | OPEN_P13N_DIALOG | Instance method | Public | Method | 20130918 | |
5 | OPEN_PARAMETER_DIALOG | Instance method | Public | Method | 20130918 | |
6 | WD_GET_API | Instance method | Public | Method | 20130918 |
Events
Class IWCI_FPM_BICS_GRID_DIALOG has no event.
Types
Class IWCI_FPM_BICS_GRID_DIALOG has no local type.
Method Signatures
Method OPEN_FILTER_DIALOG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_BICS_CHARACTERISTIC | Call by reference | Object reference (TYPE REF TO) | IF_BICS_CHARACTERISTIC | 20130918 | |||
2 | Importing | IO_BICS_QUERY | Call by reference | Object reference (TYPE REF TO) | IF_BICS_QV | 20130918 | |||
3 | Importing | IO_FPM | Call by reference | Object reference (TYPE REF TO) | IF_FPM | 20130918 | |||
4 | Importing | IO_FPM_EVENT | Call by reference | Object reference (TYPE REF TO) | CL_FPM_EVENT | 20130918 | |||
5 | Importing | IV_INSTANCE_ID | Call by reference | Type reference (TYPE) | FPM_BICS_INSTANCE_ID | 20130918 | |||
6 | Importing | IV_QUERY_ID | Call by reference | Type reference (TYPE) | RSZCOMPID | 20130918 |
Method OPEN_FILTER_DIALOG on class IWCI_FPM_BICS_GRID_DIALOG has no exception.
Method OPEN_HIERSEL_DIALOG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_BICS_CHARACTERISTIC | Call by reference | Object reference (TYPE REF TO) | IF_BICS_CHARACTERISTIC | 20130918 | |||
2 | Importing | IO_FPM | Call by reference | Object reference (TYPE REF TO) | IF_FPM | 20130918 | |||
3 | Importing | IO_FPM_EVENT | Call by reference | Object reference (TYPE REF TO) | CL_FPM_EVENT | 20130918 | |||
4 | Importing | IV_INSTANCE_ID | Call by reference | Type reference (TYPE) | FPM_BICS_INSTANCE_ID | 20130918 | |||
5 | Importing | IV_QUERY_ID | Call by reference | Type reference (TYPE) | RSZCOMPID | 20130918 |
Method OPEN_HIERSEL_DIALOG on class IWCI_FPM_BICS_GRID_DIALOG has no exception.
Method OPEN_MEASURE_DIALOG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_BICS_DATA_CELL | Call by reference | Object reference (TYPE REF TO) | IF_BICS_QV_DATA_CELL | 20130918 | |||
2 | Importing | IO_BICS_QUERY | Call by reference | Object reference (TYPE REF TO) | IF_BICS_QV | 20130918 | |||
3 | Importing | IO_FPM | Call by reference | Object reference (TYPE REF TO) | IF_FPM | 20130918 | |||
4 | Importing | IO_FPM_EVENT | Call by reference | Object reference (TYPE REF TO) | CL_FPM_EVENT | 20130918 | |||
5 | Importing | IV_INSTANCE_ID | Call by reference | Type reference (TYPE) | FPM_BICS_INSTANCE_ID | 20130918 | |||
6 | Importing | IV_QUERY_ID | Call by reference | Type reference (TYPE) | RSZCOMPID | 20130918 |
Method OPEN_MEASURE_DIALOG on class IWCI_FPM_BICS_GRID_DIALOG has no exception.
Method OPEN_P13N_DIALOG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_BICS_QUERY | Call by reference | Object reference (TYPE REF TO) | IF_BICS_QV | 20130918 | |||
2 | Importing | IO_BM_MANAGER | Call by reference | Object reference (TYPE REF TO) | CL_FPM_BICS_PERSISTENCE | 20130918 | |||
3 | Importing | IO_FPM | Call by reference | Object reference (TYPE REF TO) | IF_FPM | 20130918 | |||
4 | Importing | IO_FPM_EVENT | Call by reference | Object reference (TYPE REF TO) | CL_FPM_EVENT | 20130918 | |||
5 | Importing | IV_INSTANCE_ID | Call by reference | Type reference (TYPE) | FPM_BICS_INSTANCE_ID | 20130918 | |||
6 | Importing | IV_QUERY_ID | Call by reference | Type reference (TYPE) | RSZCOMPID | 20130918 |
Method OPEN_P13N_DIALOG on class IWCI_FPM_BICS_GRID_DIALOG has no exception.
Method OPEN_PARAMETER_DIALOG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IO_BICS_PLANNING_FUNCTION | Call by reference | Object reference (TYPE REF TO) | IF_BICS_PLANNING_FUNCTION | 20130918 | |||
2 | Importing | IO_BICS_QUERY | Call by reference | Object reference (TYPE REF TO) | IF_BICS_QV | 20130918 | |||
3 | Importing | IO_FPM | Call by reference | Object reference (TYPE REF TO) | IF_FPM | 20130918 | |||
4 | Importing | IO_FPM_EVENT | Call by reference | Object reference (TYPE REF TO) | CL_FPM_EVENT | 20130918 | |||
5 | Importing | IV_INSTANCE_ID | Call by reference | Type reference (TYPE) | FPM_BICS_INSTANCE_ID | 20130918 | |||
6 | Importing | IV_QUERY_ID | Call by reference | Type reference (TYPE) | RSZCOMPID | 20130918 |
Method OPEN_PARAMETER_DIALOG on class IWCI_FPM_BICS_GRID_DIALOG has no exception.
Method WD_GET_API Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RESULT | Value transfer | Object reference (TYPE REF TO) | IF_WD_CONTROLLER | 20130918 |
Method WD_GET_API on class IWCI_FPM_BICS_GRID_DIALOG has no exception.
History
Last changed by/on | SAP | 20140121 |
SAP Release Created in |