SAP ABAP Class IF_UC_PARAMETER_REQUEST_GUI (Communication Parameter with Request Popup)
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_UC_PARAMETER Global parameters 20010830
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_UC_PARAMETER_DATA_WD Data Class for Extended Parameters in WebDynpro Monitor 20041118
Properties
Class IF_UC_PARAMETER_REQUEST_GUI  
Short Description Communication Parameter with Request Popup    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package      
Created 20010826   SAP 
Last change 20041006   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class IF_UC_PARAMETER_REQUEST_GUI has no forward declaration.
Interfaces
Class IF_UC_PARAMETER_REQUEST_GUI has no interface implemented.
Friends
Class IF_UC_PARAMETER_REQUEST_GUI has no friend class.
Attributes
Class IF_UC_PARAMETER_REQUEST_GUI has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 GET_AREA Instance method Public Method Get active cons area 20030616
2 GET_AREA_PARAM Instance method Public Method Parameter for specific cons area 20030726
3 GET_AREA_TEXT Instance method Public Method Get description of cons area 20010827
4 GET_INCONSISTENCIES Instance method Public Method Are parameters inconsistent? 20030617
5 GET_MESSAGES Instance method Public Method Get table with messages 20020305
6 SAVE Instance method Public Method Save global parameters and current cons area 20010826
7 SET_AREA Instance method Public Method Set active cons area or temporary cons area 20010826
8 SET_PARAMETER_TEMP Instance method Public Method Set temporary parameters for temporary cons area 20030726
9 TEMP_2_ACTIVE Instance method Public Method Copy temp. tables in active settings 20010826
Events
Class IF_UC_PARAMETER_REQUEST_GUI has no event.
Types
Class IF_UC_PARAMETER_REQUEST_GUI has no local type.
Method Signatures

Method GET_AREA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_AREA Call by reference Type reference (TYPE) UC_AREA Konsolidierungsgebiet 20030616

Method GET_AREA on class IF_UC_PARAMETER_REQUEST_GUI has no exception.

Method GET_AREA_PARAM Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_PARAMETER Call by reference Type reference (TYPE) UCM_TS_PARAMETER Parameter 20030726
2 Importing I_AREA Call by reference Type reference (TYPE) UC_AREA Konsolidierungsgebiet 20030726

Method GET_AREA_PARAM on class IF_UC_PARAMETER_REQUEST_GUI has no exception.

Method GET_AREA_TEXT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting E_TXTMI Call by reference Type reference (TYPE) UC_TXTMI Mitteltext 20010827
2 Importing I_AREA Call by reference Type reference (TYPE) UC_AREA Konsolidierungsgebiet 20010827

Method GET_AREA_TEXT on class IF_UC_PARAMETER_REQUEST_GUI has no exception.

Method GET_INCONSISTENCIES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_AREAFIX Call by reference Type reference (TYPE) UC0_TS_VALUE Fixierungen 20030617
2 Exporting ET_PARAM Call by reference Type reference (TYPE) UC0_TS_VALUE Echte Parameter 20030617

Method GET_INCONSISTENCIES on class IF_UC_PARAMETER_REQUEST_GUI has no exception.

Method GET_MESSAGES Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_MESSAGE Call by reference Type reference (TYPE) UC0_T_MESSAGE Meldungen 20020305

Method GET_MESSAGES on class IF_UC_PARAMETER_REQUEST_GUI has no exception.

Method SAVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IF_TEMP Call by reference Type reference (TYPE) UC_FLG Aktive oder temporäre? 20030726

Method SAVE on class IF_UC_PARAMETER_REQUEST_GUI has no exception.

Method SET_AREA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_AREA Call by reference Type reference (TYPE) UC_AREA Konsolidierungsgebiet 20010826
2 Importing I_TEMP Call by reference Type reference (TYPE) UC_FLG Allgemeines Kennzeichen SAP Konsolidierung 20010826

Method SET_AREA on class IF_UC_PARAMETER_REQUEST_GUI has no exception.

Method SET_PARAMETER_TEMP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IT_PARAMETER Call by reference Type reference (TYPE) UCM_TS_PARAMETER Parameter 20030726

Method SET_PARAMETER_TEMP on class IF_UC_PARAMETER_REQUEST_GUI has no exception.

Method TEMP_2_ACTIVE Signature

Method TEMP_2_ACTIVE on class IF_UC_PARAMETER_REQUEST_GUI has no parameter.
Method TEMP_2_ACTIVE on class IF_UC_PARAMETER_REQUEST_GUI has no exception.
History
Last changed by/on SAP  20041006 
SAP Release Created in