SAP ABAP Class IF_UC_LAYOUT_STEP_CALLBACK (Callback of Layoutobject in the Method)
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_UC_METHOD_ALLOC Allocation Method 20000921
2 Interface implementation (CLASS c. INTERFACES i_ref)  CL_UC_METHOD_CTR Currency Translation Method 20000921
3 Interface implementation (CLASS c. INTERFACES i_ref)  CL_UC_METHOD_IUE Two-Sided Elimination 20010226
4 Interface implementation (CLASS c. INTERFACES i_ref)  CL_UC_METHOD_RECLASS Reclassification Method 20010308
5 Interface implementation (CLASS c. INTERFACES i_ref)  CL_UC_METHOD_ROUND Rounding Method 20000921
Properties
Class IF_UC_LAYOUT_STEP_CALLBACK  
Short Description Callback of Layoutobject in the Method    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package      
Created 20000920   SAP 
Last change 20041006   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class IF_UC_LAYOUT_STEP_CALLBACK has no forward declaration.
Interfaces
Class IF_UC_LAYOUT_STEP_CALLBACK has no interface implemented.
Friends
Class IF_UC_LAYOUT_STEP_CALLBACK has no friend class.
Attributes
Class IF_UC_LAYOUT_STEP_CALLBACK has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CHECK Static method Public Method Callback During Check 20000920
2 GET_GUI_DATA Static method Public Method Callback During Transfer of Data to GUI 20000920
3 GET_INITIAL_LAYOUT Static method Public Method Callback While Creating a Layout for Setting the Default 20000920
4 SET_GUI_DATA Static method Public Method Callback During Transfer of Data from GUI 20000920
Events
Class IF_UC_LAYOUT_STEP_CALLBACK has no event.
Types
Class IF_UC_LAYOUT_STEP_CALLBACK has no local type.
Method Signatures

Method CHECK Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_MESSAGE Call by reference Type reference (TYPE) UC0_T_MESSAGE Meldungen 20000920
2 Importing IO_LAYOUT Call by reference Object reference (TYPE REF TO) CL_UC_LAYOUT_STEP Layout für Step-methode 20000920
3 Importing IO_MODEL Call by reference Object reference (TYPE REF TO) IF_UC_MODEL Modell (Feldkatalog, ...) 20000921
4 Importing IT_FFIX Call by reference Type reference (TYPE) UC0_TS_FFIX Fixierte Merkmalswerte 20000921

Method CHECK on class IF_UC_LAYOUT_STEP_CALLBACK has no exception.

Method GET_GUI_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_CHAR Call by reference Type reference (TYPE) UC0_TS_FIELDTXT Feldeigenschaften 20000920
2 Changing CT_COMPONENT Call by reference Type reference (TYPE) UCU_TS_LAYOUT_COMPONENT Komponente für Layoutpflege 20000920
3 Changing CT_LSTEP_COMP Call by reference Type reference (TYPE) UCF_TS_LAYOUT_LSTEP_COMP SEM-BCS: Felder einer Komponente pro Layoutschritt 20000920
4 Changing CT_SELECTABLE_COMPONENT Call by reference Type reference (TYPE) UCU_TS_LAYOUT_SELECTABLE_COMP Wählbare Komponente 20000920
5 Importing IO_MODEL Call by reference Object reference (TYPE REF TO) IF_UC_MODEL Modell (Feldkatalog, ...) 20000920
6 Importing IT_FFIX Call by reference Type reference (TYPE) UC0_TS_FFIX Fixierte Merkmalswerte 20000920
7 Importing IT_LSTEP_LCHILD Call by reference Type reference (TYPE) UCU_T_LAYOUT_LSTEP_LCHILD Hierarchiebeziehung zwischen Layoutschritten (Layoutpflege) 20000920

Method GET_GUI_DATA on class IF_UC_LAYOUT_STEP_CALLBACK has no exception.

Method GET_INITIAL_LAYOUT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_LSTEP_COMP Call by reference Type reference (TYPE) UCF_TS_LAYOUT_LSTEP_COMP SEM-BCS: Felder einer Komponente pro Layoutschritt 20000921
2 Changing CT_LSTEP_LCHILD Call by reference Type reference (TYPE) UCF_T_LAYOUT_LSTEP_LCHILD Hierarchiebeziehung zwischen Layoutschritten (Layoutpflege) 20000921
3 Importing IO_MODEL Call by reference Object reference (TYPE REF TO) IF_UC_MODEL Modell (Feldkatalog, ...) 20000920

Method GET_INITIAL_LAYOUT on class IF_UC_LAYOUT_STEP_CALLBACK has no exception.

Method SET_GUI_DATA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_LSTEP_COMP Call by reference Type reference (TYPE) UCF_TS_LAYOUT_LSTEP_COMP SEM-BCS: Felder einer Komponente pro Layoutschritt 20000920
2 Changing CT_LSTEP_FIELD Call by reference Type reference (TYPE) UCF_TS_LAYOUT_LSTEP_FIELD SEM-BCS: Felder einer Komponente pro Layoutschritt 20010313
3 Changing CT_SELECTABLE_COMPONENT Call by reference Type reference (TYPE) UCU_TS_LAYOUT_SELECTABLE_COMP Wählbare Komponente 20000920
4 Importing IO_MODEL Call by reference Object reference (TYPE REF TO) IF_UC_MODEL Modell (Feldkatalog, ...) 20000920
5 Importing IT_FFIX Call by reference Type reference (TYPE) UC0_TS_FFIX Fixierte Merkmalswerte 20000920
6 Importing IT_LSTEP_LCHILD Call by reference Type reference (TYPE) UCU_T_LAYOUT_LSTEP_LCHILD Hierarchiebeziehung zwischen Layoutschritten (Layoutpflege) 20000920

Method SET_GUI_DATA on class IF_UC_LAYOUT_STEP_CALLBACK has no exception.
History
Last changed by/on SAP  20041006 
SAP Release Created in