SAP ABAP Class IF_SWF_RUN_WIM_DEFINITION (Workflow: Work Item Manager (Definition Data))
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface composition (i COMPRISING i_ref) | IF_SWF_RUN_WIM | Workflow: Work Item Manager | 20010125 |
2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_SWF_RUN_WIM_LOCAL | Workflow: Service Class for WIM | 20010109 |
Properties
Class | IF_SWF_RUN_WIM_DEFINITION | |
Short Description | Workflow: Work Item Manager (Definition Data) | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | ||
Created | 20010109 | SAP |
Last change | 20110908 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class IF_SWF_RUN_WIM_DEFINITION has no forward declaration.
Interfaces
Class IF_SWF_RUN_WIM_DEFINITION has no interface implemented.
Friends
Class IF_SWF_RUN_WIM_DEFINITION has no friend class.
Attributes
Class IF_SWF_RUN_WIM_DEFINITION has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Determines Node ID | 20010128 |
2 | ![]() |
Instance method | Public | Method | Determines Node | 20030403 |
3 | ![]() |
Instance method | Public | Method | Determines Properties for Step | 20011113 |
4 | ![]() |
Instance method | Public | Method | Determines Rule | 20010109 |
5 | ![]() |
Instance method | Public | Method | Determines Binding for Start Event | 20010221 |
6 | ![]() |
Instance method | Public | Method | Determines Definition of Step | 20010312 |
7 | ![]() |
Instance method | Public | Method | Gets Reference to Step | 20030417 |
8 | ![]() |
Instance method | Public | Method | Determines Task Handle | 20010111 |
9 | ![]() |
Instance method | Public | Method | Determines Binding for Completed Event | 20010221 |
10 | ![]() |
Instance method | Public | Method | Determines Expression for URL | 20010110 |
11 | ![]() |
Instance method | Public | Method | Determines Key of Workflow Definition | 20010126 |
Events
Class IF_SWF_RUN_WIM_DEFINITION has no event.
Types
Class IF_SWF_RUN_WIM_DEFINITION has no local type.
Method Signatures
Method GET_NODEID Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RE_NODEID | Value transfer | Type reference (TYPE) | SWD_NODEID | Knotennummer | 20010128 |
Method GET_NODEID on class IF_SWF_RUN_WIM_DEFINITION has no exception.
Method GET_NODE_DEFINITION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RE_NODE | Value transfer | Type reference (TYPE) | SWD_SNODES | 20030403 |
Method GET_NODE_DEFINITION on class IF_SWF_RUN_WIM_DEFINITION has no exception.
Method GET_PROPERTIES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RE_PROPERTIES | Value transfer | Type reference (TYPE) | SWDTSPROPTS | Laufzeittabelle: Eigenschaften | 20011113 |
Method GET_PROPERTIES on class IF_SWF_RUN_WIM_DEFINITION has no exception.
Method GET_RULE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_RULETYPE | Call by reference | Type reference (TYPE) | SWD_RULTYP | Workflow-Definition: Typ der Regel | 20010109 | ||
2 | ![]() |
RE_RULE | Value transfer | Type reference (TYPE) | SWD_STEP_A | Workflow-Definition: Regel | 20010109 |
Method GET_RULE on class IF_SWF_RUN_WIM_DEFINITION has no exception.
Method GET_START_EVENT_BINDING Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_CATID | Call by reference | Type reference (TYPE) | SIBFCATID | Kategorie von Objekten in Persistenten Objektreferenzen | 20010221 | ||
2 | ![]() |
IM_EVENT | Call by reference | Type reference (TYPE) | C | Ereignisname | 20010221 | ||
3 | ![]() |
IM_OBJTYPE | Call by reference | Type reference (TYPE) | C | Objekttyp | 20010221 | ||
4 | ![]() |
RE_BINDING | Value transfer | Type reference (TYPE) | SWFBNDPTAB | Tabelle mit Datenflußdefinitionen, persistente Form | 20010221 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Ereignis nicht vorhanden | 20011113 |
Method GET_STEP_DEFINITION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RE_STEP | Value transfer | Type reference (TYPE) | SWD_SSTEPS | Workflow-Definition: Schritte (Laufzeit+Definition) | 20010312 |
Method GET_STEP_DEFINITION on class IF_SWF_RUN_WIM_DEFINITION has no exception.
Method GET_STEP_HANDLE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RE_STEP_HANDLE | Value transfer | Object reference (TYPE REF TO) | IF_SWF_RUN_STEP_ATTRIBUTES | 20030417 |
Method GET_STEP_HANDLE on class IF_SWF_RUN_WIM_DEFINITION has no exception.
Method GET_TASK_HANDLE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RE_TASK_HANDLE | Value transfer | Object reference (TYPE REF TO) | IF_SWF_RUN_TASK_ATTRIBUTES | Workflow: Schnittstelle zu den Aufgaben | 20010111 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Ausnahme im WIM | 20030206 |
Method GET_TERM_EVENT_BINDING Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IM_CATID | Call by reference | Type reference (TYPE) | SIBFCATID | Kategorie von Objekten in Persistenten Objektreferenzen | 20010221 | ||
2 | ![]() |
IM_EVENT | Call by reference | Type reference (TYPE) | C | Ereignisname | 20010221 | ||
3 | ![]() |
IM_OBJTYPE | Call by reference | Type reference (TYPE) | C | Objekttyp | 20010221 | ||
4 | ![]() |
RE_BINDING | Value transfer | Type reference (TYPE) | SWFBNDPTAB | Tabelle mit Datenflußdefinitionen, persistente Form | 20010221 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Ereignis nicht vorhanden | 20011113 |
Method GET_URL_EXPRESSION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RE_EXPRESSION | Value transfer | Type reference (TYPE) | SWA_EXPR | Ausdruck | 20010110 |
Method GET_URL_EXPRESSION on class IF_SWF_RUN_WIM_DEFINITION has no exception.
Method GET_WFDWIZ Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RE_WFDWIZ | Value transfer | Type reference (TYPE) | SWD_WFDWIZ | Workflow-Definition: Keystruktur fuer alle DB-Tabellen | 20010126 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | ![]() |
Ausnahme im WIM | 20030206 |
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in |