SAP ABAP Class IF_SCV_SERIES (Test Series)
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  CL_SCV_SERIES Test Series 20091123
Properties
Class IF_SCV_SERIES  
Short Description Test Series    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package      
Created 20091123   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ABAP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 IF_SCV_MEASUREMENT Forward declaration interface (INTERFACE i DEFINITION DEF...  Forward declaration interface (INTERFACE i DEFINITION DEF...
Interfaces
Class IF_SCV_SERIES has no interface implemented.
Friends
Class IF_SCV_SERIES has no friend class.
Attributes
Class IF_SCV_SERIES has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 ASSIGN_MEASUREMENT Instance method Public Method Adds an Existing Measurement 20091125
2 CREATE_MEASUREMENT Instance method Public Method Creates a New Test Series 20091123
3 GET_CHANGED_AT Instance method Public Method Changed At 20091202
4 GET_CHANGED_BY Instance method Public Method Changed by 20091202
5 GET_LOCAL_SERVER_ONLY Instance method Public Method Displays Setting for Server-Local Measurements 20091123
6 GET_NAME Instance method Public Method Returns the name of the measurement 20091123
7 GET_RESULT_CONFIGURATION Instance method Public Method Displays interface for configuring results 20091123
8 GET_SELECTION Instance method Public Method Returns the underlying object selection 20091123
9 GET_TESTKEY_EXPIRATION Instance method Public Method Returns expiration date for text key and raw data 20091124
10 GET_USERS Instance method Public Method Returns user whose activities are to be measured 20091123
11 SET_LOCAL_SERVER_ONLY Instance method Public Method Sets setting for server-local measurement 20091123
12 SET_NAME Instance method Public Method Sets the Name 20091123
13 SET_RESULT_CONFIGURATION Instance method Public Method Sets interface for configuring results 20091124
14 SET_SELECTION Instance method Public Method Sets underlying object selection 20091124
15 SET_TESTKEY_EXPIRATION Instance method Public Method Sets expiration date for text key and raw data 20091124
16 SET_USERS Instance method Public Method Sets user whose activity is to be measured 20091123
17 UNASSIGN_MEASUREMENT Instance method Public Method Removes assignment to a measurement 20091125
Events
Class IF_SCV_SERIES has no event.
Types
# Type Visibility Typing Associated Type Description Created on Type Source
1 TAB Public See coding Table with Test Series 20091123 tab TYPE STANDARD TABLE OF REF TO if_scv_series WITH DEFAULT KEY
Method Signatures

Method ASSIGN_MEASUREMENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_MEASUREMENT Call by reference Object reference (TYPE REF TO) IF_SCV_MEASUREMENT Einzelne oder kombinierte Abdeckungsmessung 20091125

Method ASSIGN_MEASUREMENT on class IF_SCV_SERIES has no exception.

Method CREATE_MEASUREMENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_NAME Call by reference Type reference (TYPE) CVA_MEASUREMENT_NAME Name der Messung 20091124
2 Returning R_MEASUREMENT Value transfer Object reference (TYPE REF TO) IF_SCV_MEASUREMENT Einzelne oder kombinierte Abdeckungsmessung 20091123
# Exception Resumable Description Created on
1 CX_SCV_EXECUTION_ERROR Statische Exceptions der SCV API 20091201

Method GET_CHANGED_AT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_TIMESTAMP Value transfer Type reference (TYPE) TIMESTAMP UTC-Zeitstempel in Kurzform (JJJJMMTThhmmss) 20091202

Method GET_CHANGED_AT on class IF_SCV_SERIES has no exception.

Method GET_CHANGED_BY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_USER Value transfer Type reference (TYPE) CVA_CHANGED_BY Geändert von 20091202

Method GET_CHANGED_BY on class IF_SCV_SERIES has no exception.

Method GET_LOCAL_SERVER_ONLY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_RESULT Value transfer Type reference (TYPE) CVA_LOCAL_SERVER_ONLY TRUE, falls nur auf dem lokalen Server gemessen wird 20091123

Method GET_LOCAL_SERVER_ONLY on class IF_SCV_SERIES has no exception.

Method GET_NAME Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_NAME Value transfer Type reference (TYPE) CVA_SERIES_NAME Name der Messreihe 20091123

Method GET_NAME on class IF_SCV_SERIES has no exception.

Method GET_RESULT_CONFIGURATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_CONFIGURATION Value transfer Object reference (TYPE REF TO) IF_SCV_RESULT_CONFIGURATION Ermöglicht die Feinkonfiguration des Ergebnisbaums 20091123

Method GET_RESULT_CONFIGURATION on class IF_SCV_SERIES has no exception.

Method GET_SELECTION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_SELECTION Value transfer Object reference (TYPE REF TO) IF_SCV_SELECTION Objektauswahl zum Erzeugen eines Ergebnisbaums 20091123

Method GET_SELECTION on class IF_SCV_SERIES has no exception.

Method GET_TESTKEY_EXPIRATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_TESTKEY_EXPIRATION Value transfer Object reference (TYPE REF TO) CL_SCV_EXPIRATION Haltbarkeitsdatum 20091124

Method GET_TESTKEY_EXPIRATION on class IF_SCV_SERIES has no exception.

Method GET_USERS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning R_USERS Value transfer Type reference (TYPE) IF_SCV_MEASUREMENT=>USERS Tabelle von Benutzern 20091123

Method GET_USERS on class IF_SCV_SERIES has no exception.

Method SET_LOCAL_SERVER_ONLY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_LOCAL_SERVER_ONLY Call by reference Type reference (TYPE) ABAP_BOOL TRUE, falls nur auf dem lokalen Server gemessen wird 20091123

Method SET_LOCAL_SERVER_ONLY on class IF_SCV_SERIES has no exception.

Method SET_NAME Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_NAME Call by reference Type reference (TYPE) CVA_SERIES_NAME Name der Messreihe 20091123

Method SET_NAME on class IF_SCV_SERIES has no exception.

Method SET_RESULT_CONFIGURATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_CONFIGURATION Call by reference Object reference (TYPE REF TO) IF_SCV_RESULT_CONFIGURATION Ermöglicht die Feinkonfiguration des Ergebnisbaums 20091124

Method SET_RESULT_CONFIGURATION on class IF_SCV_SERIES has no exception.

Method SET_SELECTION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_SELECTION Call by reference Object reference (TYPE REF TO) IF_SCV_SELECTION Objektauswahl zum Erzeugen eines Ergebnisbaums 20091124

Method SET_SELECTION on class IF_SCV_SERIES has no exception.

Method SET_TESTKEY_EXPIRATION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_TESTKEY_EXPIRATION Call by reference Object reference (TYPE REF TO) CL_SCV_EXPIRATION Haltbarkeitsdatum 20091124

Method SET_TESTKEY_EXPIRATION on class IF_SCV_SERIES has no exception.

Method SET_USERS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_USERS Call by reference Type reference (TYPE) IF_SCV_MEASUREMENT=>USERS Tabelle von Benutzern 20091123

Method SET_USERS on class IF_SCV_SERIES has no exception.

Method UNASSIGN_MEASUREMENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing I_MEASUREMENT Call by reference Object reference (TYPE REF TO) IF_SCV_MEASUREMENT Einzelne oder kombinierte Abdeckungsmessung 20091125

Method UNASSIGN_MEASUREMENT on class IF_SCV_SERIES has no exception.
History
Last changed by/on SAP  20110908 
SAP Release Created in