SAP ABAP Class IF_GHO_QTY_CONVERSION (Interface for BAdI: BADI_GHO_QTY_CONVERSION)
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Interface composition (i COMPRISING i_ref)  IF_BADI_INTERFACE Tag Interface for BAdIs 20090821
Properties
Class IF_GHO_QTY_CONVERSION  
Short Description Interface for BAdI: BADI_GHO_QTY_CONVERSION    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package      
Created 20090821   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class IF_GHO_QTY_CONVERSION has no forward declaration.
Interfaces
Class IF_GHO_QTY_CONVERSION has no interface implemented.
Friends
Class IF_GHO_QTY_CONVERSION has no friend class.
Attributes
Class IF_GHO_QTY_CONVERSION has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 GET_PARAMETER Instance method Public Method Get the Conversion Parameters 20090821
2 GET_STD_UOMS_FOR_DIMID Instance method Public Method Fetch all standard uom for given dimension 20100505
3 GET_STD_UOM_FOR_DIMID Instance method Public Method Fetch the standard uom for given dimension 20091203
4 GET_TANK_IDS Instance method Public Method Get all Tank Sequence Numbers 20091201
5 GET_TANK_PARAMETER Instance method Public Method Get the Tank Parameters 20091026
6 GET_UOMS_FOR_UOM_GRP Instance method Public Method Fetch all uom's for given uom group 20091208
7 PERFORM_QTY_CONVERSION Instance method Public Method Perform the Quantity Conversion 20090821
8 PERFORM_TANK_QTY_CONVERSION Instance method Public Method Perform Tank Quantity conversion 20091026
Events
Class IF_GHO_QTY_CONVERSION has no event.
Types
Class IF_GHO_QTY_CONVERSION has no local type.
Method Signatures

Method GET_PARAMETER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing ET_PARAM_LIST Call by reference Type reference (TYPE) GHO_T_MEAS_PARAM Table Type showcasing GHO Parameter & Description 20090821

Method GET_PARAMETER on class IF_GHO_QTY_CONVERSION has no exception.

Method GET_STD_UOMS_FOR_DIMID Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing ET_STD_UOM Call by reference Type reference (TYPE) GHO_T_MEAS_UOM Table type for UOM 20100505
2 Importing IV_DIMID Call by reference Type reference (TYPE) DIMID Dimension key 20100505
3 Importing IV_UOM_GRP Call by reference Type reference (TYPE) CHAR3 3-Byte field 20100505

Method GET_STD_UOMS_FOR_DIMID on class IF_GHO_QTY_CONVERSION has no exception.

Method GET_STD_UOM_FOR_DIMID Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing EV_STD_UOM Call by reference Type reference (TYPE) MSEHI Unit of Measurement 20091203
2 Importing IV_DIMID Call by reference Type reference (TYPE) DIMID Dimension key 20091203
3 Importing IV_UOM_GRP Call by reference Type reference (TYPE) CHAR3 3-Byte field 20091203

Method GET_STD_UOM_FOR_DIMID on class IF_GHO_QTY_CONVERSION has no exception.

Method GET_TANK_IDS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing ET_TANK_ID Call by reference Type reference (TYPE) GHO_T_TANK_GD GHO - Tank ID 20091201
2 Importing IV_LGORT Call by reference Type reference (TYPE) LGORT_D Storage Location 20091201
3 Importing IV_WERKS Call by reference Type reference (TYPE) WERKS_D Plant 20091201

Method GET_TANK_IDS on class IF_GHO_QTY_CONVERSION has no exception.

Method GET_TANK_PARAMETER Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing ET_PARAM_LIST Call by reference Type reference (TYPE) GHO_T_MEAS_TANK_PARAMS Table Type showcasing GHO Parameter & Description 20091027

Method GET_TANK_PARAMETER on class IF_GHO_QTY_CONVERSION has no exception.

Method GET_UOMS_FOR_UOM_GRP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing ET_UOMS Call by reference Type reference (TYPE) GHO_T_MSEHI Table type for uom's 20091208
2 Importing IV_UOM_GRP Call by reference Type reference (TYPE) CHAR3 3-Byte field 20091208

Method GET_UOMS_FOR_UOM_GRP on class IF_GHO_QTY_CONVERSION has no exception.

Method PERFORM_QTY_CONVERSION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing ET_MESSAGES Call by reference Type reference (TYPE) BAPIRET2_T Return parameter table 20100108
2 Changing ET_PARAMS Call by reference Type reference (TYPE) GHO_T_QTY_CONVERSION Table Type for QCI Parameter Table 20110131
3 Changing ET_STD_VAL Call by reference Type reference (TYPE) GHO_T_IMRG_STD Table Type for Standardized Values 20091008
4 Importing IS_MDOCM Call by reference Type reference (TYPE) IMRC_MDOCM Measurement Document 20091008
5 Importing IT_PARAMS Call by reference Type reference (TYPE) GHO_T_MEAS_READING 20091008

Method PERFORM_QTY_CONVERSION on class IF_GHO_QTY_CONVERSION has no exception.

Method PERFORM_TANK_QTY_CONVERSION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_MEAS_QTY_CONV Call by reference Type reference (TYPE) GHO_T_MEAS_READING GHO Measurement Reading 20091102
2 Changing ET_MESSAGES Call by reference Type reference (TYPE) BAPIRET2_T Return parameter table 20091103
3 Importing IV_LGORT Call by reference Type reference (TYPE) LGORT_D Material Master View on Storage Location and Batch Selection 20091029
4 Importing IV_OBJECT_ID Call by reference Type reference (TYPE) GHO_MEAS_SSEQNR GHO Sequence number of SO assigned to storage location 20091029
5 Importing IV_TIMESTAMP Call by reference Type reference (TYPE) GHO_MEAS_TIMESTAMP GHO Measurement Time Stamp 20091029
6 Importing IV_WERKS Call by reference Type reference (TYPE) WERKS_D Plant 20091029

Method PERFORM_TANK_QTY_CONVERSION on class IF_GHO_QTY_CONVERSION has no exception.
History
Last changed by/on SAP  20110908 
SAP Release Created in