SAP ABAP Class IF_EX_WSTRN_ALLOC_DIALOG (Business add-in interface IF_EX_WSTRN_ALLOC_DIALOG)
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EXM_IM_WSTRN_ALLOC_DIALOG | Example implementation for WSTRN_ALLOC_DIALOG | 20020415 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_WSTRN_ALLOC_DIALOG | BAdI class CL_EX_WSTRN_ALLOC_DIALOG | 20020415 |
Properties
| Class | IF_EX_WSTRN_ALLOC_DIALOG | |
| Short Description | Business add-in interface IF_EX_WSTRN_ALLOC_DIALOG | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 1 | |
| Package | ||
| Created | 20020415 | SAP |
| Last change | 20050411 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 2 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class IF_EX_WSTRN_ALLOC_DIALOG has no interface implemented.
Friends
Class IF_EX_WSTRN_ALLOC_DIALOG has no friend class.
Attributes
Class IF_EX_WSTRN_ALLOC_DIALOG has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Process your added functions | 20020415 | |
| 2 | Instance method | Public | Method | Set up the prepack allocation ALV grid toolbar | 20020415 | |
| 3 | Instance method | Public | Method | Set up the variant allocation ALV grid toolbar | 20020415 |
Events
Class IF_EX_WSTRN_ALLOC_DIALOG has no event.
Types
Class IF_EX_WSTRN_ALLOC_DIALOG has no local type.
Method Signatures
Method COMMAND_TOOLBAR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IM_CURR_ASORT | Call by reference | Type reference (TYPE) | ASORT | Aktuell ausgewähltes Sortiment | 20020415 | |||
| 2 | IM_CURR_SBELN | Call by reference | Type reference (TYPE) | SBELN | Aktuell ausgewählte Aufteilregel | 20020415 | |||
| 3 | IM_O_ALLOC_PLANNING | Call by reference | Object reference (TYPE REF TO) | CL_WSTN_PP_ALLOC_PLANNING | Kapselung der Aufteilungsplanungsdaten | 20020415 | |||
| 4 | IM_O_PP_ALVGRID | Call by reference | Object reference (TYPE REF TO) | CL_GUI_ALV_GRID | ALV-Grid für Lotaufteilung | 20020415 | |||
| 5 | IM_O_PREPACK | Call by reference | Object reference (TYPE REF TO) | CL_WSTN_PREPACK_DEFN | Kapselung der Lotdatendefinition | 20020415 | |||
| 6 | IM_O_VAR_ALVGRID | Call by reference | Object reference (TYPE REF TO) | CL_GUI_ALV_GRID | ALV-Grid für Variantenaufteilung | 20020415 | |||
| 7 | IM_T_PP_DIALOG | Call by reference | Object reference (TYPE REF TO) | DATA | Tabelle hinter dem ALV-Grid für Lotaufteilung | 20020415 | |||
| 8 | IM_T_VAR_DIALOG | Call by reference | Object reference (TYPE REF TO) | DATA | Tabelle hinter dem ALV-Grid für Variantenaufteilung | 20020415 | |||
| 9 | IM_UCOMM | Call by reference | Type reference (TYPE) | SY-UCOMM | Bilder, Funktionscode ausgelöst durch PAI | 20020415 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Fehler bei Methode COMMAND_TOOLBAR | 20020415 |
Method SETUP_PP_TOOLBAR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CH_T_CONTEXT | Call by reference | Type reference (TYPE) | TTB_BTNMNU | Toolbar Context Menu | 20050328 | |||
| 2 | CH_T_TOOLBAR | Call by reference | Type reference (TYPE) | TTB_BUTTON | Drucktasten der Toolbar | 20020415 | |||
| 3 | IM_DISPLAY_ONLY | Call by reference | Type reference (TYPE) | XFELD | Gibt den Anzeigemodus an | 20020415 |
Method SETUP_PP_TOOLBAR on class IF_EX_WSTRN_ALLOC_DIALOG has no exception.
Method SETUP_VAR_TOOLBAR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CH_T_CONTEXT | Call by reference | Type reference (TYPE) | TTB_BTNMNU | Toolbar Context Menu | 20050328 | |||
| 2 | CH_T_TOOLBAR | Call by reference | Type reference (TYPE) | TTB_BUTTON | Drucktasten der Toolbar | 20020415 | |||
| 3 | IM_DISPLAY_ONLY | Call by reference | Type reference (TYPE) | XFELD | Gibt den Anzeigemodus an | 20020415 |
Method SETUP_VAR_TOOLBAR on class IF_EX_WSTRN_ALLOC_DIALOG has no exception.
History
| Last changed by/on | SAP | 20050411 |
| SAP Release Created in |