SAP ABAP Class IF_EX_WRF_MAT_MAINTENANCE (BAdI Interface IF_EX_WRF_MAT_MAINTENANCE)
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_DEF_IM_WRF_MAT_MAINTENANCE | Default Implementation for BAdI Definition WRF_MAT_MAINTENA | 20050422 |
2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_WRF_MAT_MAINTENANCE | BAdI Class CL_EX_WRF_MAT_MAINTENANCE | 20030605 |
Properties
Class | IF_EX_WRF_MAT_MAINTENANCE | |
Short Description | BAdI Interface IF_EX_WRF_MAT_MAINTENANCE | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 1 | |
Package | ||
Created | 20030605 | SAP |
Last change | 20050428 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class IF_EX_WRF_MAT_MAINTENANCE has no forward declaration.
Interfaces
Class IF_EX_WRF_MAT_MAINTENANCE has no interface implemented.
Friends
Class IF_EX_WRF_MAT_MAINTENANCE has no friend class.
Attributes
Class IF_EX_WRF_MAT_MAINTENANCE has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Activate FCODE and Subscreen Processing | 20040406 |
2 | ![]() |
Instance method | Public | Method | Check/Change Data Before Sending Main Screen | 20040927 |
3 | ![]() |
Instance method | Public | Method | Check/Change Data Before Update | 20040927 |
4 | ![]() |
Instance method | Public | Method | Check/Change the Column Text/Item | 20050422 |
5 | ![]() |
Instance method | Public | Method | Customer-Specific Data Object / Update | 20030828 |
6 | ![]() |
Instance method | Public | Method | NOT NEEDED | 20040419 |
7 | ![]() |
Instance method | Public | Method | Process Function Code +CUS_01 | 20040419 |
8 | ![]() |
Instance method | Public | Method | Process Function Code +CUS_02 | 20040419 |
9 | ![]() |
Instance method | Public | Method | Process Function Code +CUS_03 | 20040419 |
10 | ![]() |
Instance method | Public | Method | Transfer ALE Instance to Subscreen | 20040419 |
Events
Class IF_EX_WRF_MAT_MAINTENANCE has no event.
Types
Class IF_EX_WRF_MAT_MAINTENANCE has no local type.
Method Signatures
Method ACTIVATE_EXTENSION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_CUSTOM_SCREEN | Call by reference | Type reference (TYPE) | BOOLEAN | Kundenspezifischer Screen | 20040406 | ||
2 | ![]() |
EV_FCODE_01 | Call by reference | Type reference (TYPE) | BOOLEAN | Kundenspezifischer Funktionscode | 20040406 | ||
3 | ![]() |
EV_FCODE_02 | Call by reference | Type reference (TYPE) | BOOLEAN | Kundenspezifischer Funktionscode | 20040406 | ||
4 | ![]() |
EV_FCODE_03 | Call by reference | Type reference (TYPE) | BOOLEAN | Kundenspezifischer Funktionscode | 20040406 | ||
5 | ![]() |
EV_STATE_ICON | Call by reference | Type reference (TYPE) | BOOLEAN | Status-ICON im Baum anzeigen | 20040627 |
Method ACTIVATE_EXTENSION on class IF_EX_WRF_MAT_MAINTENANCE has no exception.
Method CHECK_DATA_BEFORE_DIALOG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_ALE_OBJECT | Value transfer | Object reference (TYPE REF TO) | CL_MATERIAL_MAINTAINDATA_ALE | Materialcontainer Verbuchung | 20040927 | ||
2 | ![]() |
IV_DATA_OBJECT | Value transfer | Object reference (TYPE REF TO) | CL_MATERIAL_MAINTAINDATA | Materialcontainer Dialog | 20040927 |
Method CHECK_DATA_BEFORE_DIALOG on class IF_EX_WRF_MAT_MAINTENANCE has no exception.
Method CHECK_DATA_BEFORE_POSTING Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CV_EXIT_FUNCTION | Call by reference | Type reference (TYPE) | UI_FUNC | Funktionscode | 20040927 | ||
2 | ![]() |
IV_ALE_OBJECT | Value transfer | Object reference (TYPE REF TO) | CL_MATERIAL_MAINTAINDATA_ALE | Materialcontainer Verbuchung | 20040927 | ||
3 | ![]() |
IV_DATA_OBJECT | Value transfer | Object reference (TYPE REF TO) | CL_MATERIAL_MAINTAINDATA | Materialcontainer Dialog | 20040927 |
Method CHECK_DATA_BEFORE_POSTING on class IF_EX_WRF_MAT_MAINTENANCE has no exception.
Method CHECK_FCAT_FOR_VARIABLE_DATA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CT_FCAT | Call by reference | Type reference (TYPE) | LVC_T_FCAT | Feldkatalog für ListViewerControl | 20050422 |
Method CHECK_FCAT_FOR_VARIABLE_DATA on class IF_EX_WRF_MAT_MAINTENANCE has no exception.
Method GET_CUSTOM_DATA_OBJECT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CV_INSTANCE | Call by reference | Object reference (TYPE REF TO) | IF_MATERIAL_MAINTAINDATA | Datencontainer Materialrumpf | 20030828 |
Method GET_CUSTOM_DATA_OBJECT on class IF_EX_WRF_MAT_MAINTENANCE has no exception.
Method GET_DATA_FROM_SCREEN Signature
Method GET_DATA_FROM_SCREEN on class IF_EX_WRF_MAT_MAINTENANCE has no parameter.
Method GET_DATA_FROM_SCREEN on class IF_EX_WRF_MAT_MAINTENANCE has no exception.
Method PROCESS_FCODE_01 Signature
Method PROCESS_FCODE_01 on class IF_EX_WRF_MAT_MAINTENANCE has no parameter.
Method PROCESS_FCODE_01 on class IF_EX_WRF_MAT_MAINTENANCE has no exception.
Method PROCESS_FCODE_02 Signature
Method PROCESS_FCODE_02 on class IF_EX_WRF_MAT_MAINTENANCE has no parameter.
Method PROCESS_FCODE_02 on class IF_EX_WRF_MAT_MAINTENANCE has no exception.
Method PROCESS_FCODE_03 Signature
Method PROCESS_FCODE_03 on class IF_EX_WRF_MAT_MAINTENANCE has no parameter.
Method PROCESS_FCODE_03 on class IF_EX_WRF_MAT_MAINTENANCE has no exception.
Method PUT_DATA_TO_SCREEN Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_ALE_OBJECT | Value transfer | Object reference (TYPE REF TO) | CL_MATERIAL_MAINTAINDATA_ALE | Materialcontainer Verbuchung | 20040419 | ||
2 | ![]() |
IV_DATA_OBJECT | Value transfer | Object reference (TYPE REF TO) | CL_MATERIAL_MAINTAINDATA | Materialcontainer Dialog | 20040419 |
Method PUT_DATA_TO_SCREEN on class IF_EX_WRF_MAT_MAINTENANCE has no exception.
History
Last changed by/on | SAP | 20050428 |
SAP Release Created in |