SAP ABAP Class IF_EX_SFWS_QPCP (Interface for BAdI: BADI_SFWS_QPCP)
Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Interface composition (i COMPRISING i_ref) | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20070704 |
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_IM_SFWS_QPCP | Integration of Control Plan Fields in EWB | 20070704 |
Properties
Class | IF_EX_SFWS_QPCP | |
Short Description | Interface for BAdI: BADI_SFWS_QPCP | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | ||
Created | 20070704 | SAP |
Last change | 20100310 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class IF_EX_SFWS_QPCP has no forward declaration.
Interfaces
Class IF_EX_SFWS_QPCP has no interface implemented.
Friends
Class IF_EX_SFWS_QPCP has no friend class.
Attributes
Class IF_EX_SFWS_QPCP has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Adjust "No Inspection" Indicator, If Required | 20070717 |
2 | ![]() |
Instance method | Public | Method | Adjust "No Inspection" Indicator, If Required | 20070717 |
3 | ![]() |
Instance method | Public | Method | Delete "No Inspection" Indicator | 20070717 |
4 | ![]() |
Instance method | Public | Method | Control Fields: Control According to Client Settings | 20070716 |
5 | ![]() |
Instance method | Public | Method | Set Indicator from "No Inspection" to "Not Ready for Input" | 20070717 |
6 | ![]() |
Instance method | Public | Method | Control Fields: Control According to Client Settings | 20070822 |
Events
Class IF_EX_SFWS_QPCP has no event.
Types
Class IF_EX_SFWS_QPCP has no local type.
Method Signatures
Method ADJUST_NO_INSPECTION_INDICATOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_NO_INSPECTION | Call by reference | Type reference (TYPE) | QP_NO_INSPECTION | Prüfmerkmal nicht in Prüflos übernehmen | 20070717 | ||
2 | ![]() |
IV_ESTUKZ1 | Call by reference | Type reference (TYPE) | QESTU1 | Keine Merkmalserfassung | 20070717 |
Method ADJUST_NO_INSPECTION_INDICATOR on class IF_EX_SFWS_QPCP has no exception.
Method ADJUST_NO_INSPECTION_IND_QPAA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_NO_INSPECTION | Call by reference | Type reference (TYPE) | QP_NO_INSPECTION | Prüfmerkmal nicht in Prüflos übernehmen | 20070717 | ||
2 | ![]() |
IV_ESTUKZ | Call by reference | Type reference (TYPE) | QESTUKZ | Erfassungsart | 20070717 |
Method ADJUST_NO_INSPECTION_IND_QPAA on class IF_EX_SFWS_QPCP has no exception.
Method CLEAR_NO_INSPECTION_INDICATOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_NO_INSPECTION | Call by reference | Type reference (TYPE) | QP_NO_INSPECTION | Prüfmerkmal nicht in Prüflos übernehmen | 20070717 |
Method CLEAR_NO_INSPECTION_INDICATOR on class IF_EX_SFWS_QPCP has no exception.
Method FIELD_MODIFICATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CV_SCREEN | Call by reference | Type reference (TYPE) | SCREEN | Strukturbeschreibung für System-Datenobjekt SCREEN | 20070716 | ||
2 | ![]() |
IV_ACTYPE | Call by reference | Type reference (TYPE) | C | Aktivität | 20070905 |
Method FIELD_MODIFICATION on class IF_EX_SFWS_QPCP has no exception.
Method MAKE_NO_INSPECTION_INACTIVE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CV_SCREEN | Call by reference | Type reference (TYPE) | SCREEN | Strukturbeschreibung für System-Datenobjekt SCREEN | 20070717 | ||
2 | ![]() |
IV_ESTUKZ | Call by reference | Type reference (TYPE) | CHA_CLASS_DATA-ESTUKZ | Erfassungsart | 20070822 |
Method MAKE_NO_INSPECTION_INACTIVE on class IF_EX_SFWS_QPCP has no exception.
Method TABLE_COLUMN_MODIFIATION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CV_INVISIBLE | Call by reference | Type reference (TYPE) | CHAR1 | Unsichtbar ? | 20070822 | ||
2 | ![]() |
CV_VISLENGTH | Call by reference | Type reference (TYPE) | ICONLENGTH | Ausgabelänge | 20070822 | ||
3 | ![]() |
IV_GROUP3 | Call by reference | Type reference (TYPE) | SCREEN-GROUP3 | Screen-Gruppe | 20070824 |
Method TABLE_COLUMN_MODIFIATION on class IF_EX_SFWS_QPCP has no exception.
History
Last changed by/on | SAP | 20100310 |
SAP Release Created in |