SAP ABAP Class IF_EX_IERI_IPW4_INTERNAL1 (BAdI Interface IF_EX_IERI_IPW4_INTERNAL1)
Meta Relationship - Using
| # | Relationship type | Using | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface composition (i COMPRISING i_ref) | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20050406 |
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_DEF_IM_IERI_IPW4_INTERNAL1 | Default Implementation for Business Add-In Definition IERI_I | 20011116 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_IERI_IPW4_INTERNAL1 | BAdI Class CL_EX_IERI_IPW4_INTERNAL1 | 20091215 |
| 3 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_IM_DIAD_CC_IPW4_INT | Imp. class for BAdI imp. DIAD_CC_IPW4_INT | 20040709 |
Properties
| Class | IF_EX_IERI_IPW4_INTERNAL1 | |
| Short Description | BAdI Interface IF_EX_IERI_IPW4_INTERNAL1 | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 1 | |
| Package | ||
| Created | 20011115 | SAP |
| Last change | 20100310 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
Class IF_EX_IERI_IPW4_INTERNAL1 has no forward declaration.
Interfaces
Class IF_EX_IERI_IPW4_INTERNAL1 has no interface implemented.
Friends
Class IF_EX_IERI_IPW4_INTERNAL1 has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Constant | Public | Type reference (TYPE) | BALNREXT | 'IE4N_PROCESS_MESSAGES' | Application Log: External ID | 20011116 | ||
| 2 | Constant | Public | Type reference (TYPE) | BALNREXT | 'IE4N_TECHNICAL_MESSAGES' | Application Log: External ID | 20011116 | ||
| 3 | Constant | Public | Type reference (TYPE) | CHAR10 | 'Install' | Character field length = 10 | 20011116 | ||
| 4 | Constant | Public | Type reference (TYPE) | CHAR10 | 'Remove' | Character field length = 10 | 20011116 | ||
| 5 | Constant | Public | Type reference (TYPE) | CHAR10 | 'Swap' | Character field length = 10 | 20011116 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | IS-specific check if message severity can be customized | 20011115 | |
| 2 | Instance method | Public | Method | IS changes to data before starting install / remove process | 20011115 | |
| 3 | Instance method | Public | Method | Convert time and date into another time zone | 20011207 | |
| 4 | Instance method | Public | Method | Get time zone into which time has to be converted | 20011207 | |
| 5 | Instance method | Public | Method | Message handling in FU IPW5 | 20011116 | |
| 6 | Instance method | Public | Method | Fill application log | 20011123 | |
| 7 | Instance method | Public | Method | IS specific program part for unforced fit | 20020508 | |
| 8 | Instance method | Public | Method | IS-specific error handling after serial number --> full equi | 20011115 | |
| 9 | Instance method | Public | Method | IS specific updates to reservation before DB read | 20030509 |
Events
Class IF_EX_IERI_IPW4_INTERNAL1 has no event.
Types
Class IF_EX_IERI_IPW4_INTERNAL1 has no local type.
Method Signatures
Method ADJUST_MESSAGETYPE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CV_MSGTY | Call by reference | Type reference (TYPE) | SYMSGTY | Messages, message type | 20011115 | |||
| 2 | IV_ARBGB | Call by reference | Type reference (TYPE) | SYMSGID | Messages, Message Class | 20011115 | |||
| 3 | IV_MSGNR | Call by reference | Type reference (TYPE) | SYMSGNO | Messages, Message Number | 20011115 |
Method ADJUST_MESSAGETYPE on class IF_EX_IERI_IPW4_INTERNAL1 has no exception.
Method BEFORE_POSTING Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CS_HEQUI | Call by reference | Type reference (TYPE) | V_EQUI | Generated Table for View V_EQUI | 20020131 | |||
| 2 | CS_HIFLO | Call by reference | Type reference (TYPE) | IFLO | Generated Table for View IFLO | 20020131 | |||
| 3 | CS_IPW4_COM_1 | Call by reference | Type reference (TYPE) | IPW4_COM | Communication structure for Equipment install/removal trans. | 20011115 | |||
| 4 | CS_IPW4_COM_2 | Call by reference | Type reference (TYPE) | IPW4_COM | Communication structure for Equipment install/removal trans. | 20011115 | |||
| 5 | CS_SEQUI | Call by reference | Type reference (TYPE) | V_EQUI | Generated Table for View V_EQUI | 20020131 | |||
| 6 | IV_SIMULATION | Call by reference | Type reference (TYPE) | XFELD | Checkbox | 20020131 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | internal_error | 20011123 |
Method CONVERT_TIME Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_DATUM | Call by reference | Type reference (TYPE) | INSTALLDAT | Date on which installation location of equipment was changed | 20011207 | |||
| 2 | EV_UZEIT | Call by reference | Type reference (TYPE) | INSTALLTIM | Time at which the InstallLoc of the equipment was changed | 20011207 | |||
| 3 | IV_DATUM | Call by reference | Type reference (TYPE) | INSTALLDAT | Date on which installation location of equipment was changed | 20011207 | |||
| 4 | IV_TZONE_FROM | Call by reference | Type reference (TYPE) | TZNZONE | Time zone | 20011207 | |||
| 5 | IV_TZONE_INTO | Call by reference | Type reference (TYPE) | TZNZONE | Time zone | 20011207 | |||
| 6 | IV_UZEIT | Call by reference | Type reference (TYPE) | INSTALLTIM | Time at which the InstallLoc of the equipment was changed | 20011207 |
Method CONVERT_TIME on class IF_EX_IERI_IPW4_INTERNAL1 has no exception.
Method GET_TZONE_INTO Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | EV_NO_CONVERSION | Call by reference | Type reference (TYPE) | FLAG | General Flag | 20011207 | |||
| 2 | EV_TZONE_INTO | Call by reference | Type reference (TYPE) | TZNZONE | Time zone | 20011207 |
Method GET_TZONE_INTO on class IF_EX_IERI_IPW4_INTERNAL1 has no exception.
Method IPW5_MESSAGE_HANDLING Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CS_IPW4_COM | Call by reference | Type reference (TYPE) | IPW4_COM | Communication structure for Equipment install/removal trans. | 20011116 | |||
| 2 | IV_ARBGB | Call by reference | Type reference (TYPE) | SYMSGID | Messages, Message Class | 20011116 | |||
| 3 | IV_LOG_HANDLE | Call by reference | Type reference (TYPE) | BALLOGHNDL | Application Log: Log handle | 20011116 | |||
| 4 | IV_MSGNR | Call by reference | Type reference (TYPE) | SYMSGNO | System message number | 20011116 | |||
| 5 | IV_MSGTY | Call by reference | Type reference (TYPE) | SYMSGTY | Messages, message type | 20011116 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Error concerning removal of equipment | 20011116 | ||
| 2 | Error concerning installation of equipment | 20011116 |
Method IPW5_SETUP_LOGS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CT_LOG_HANDLE | Call by reference | Type reference (TYPE) | BAL_T_LOGH | Application Log: Log Handle Table | 20011123 | |||
| 2 | CV_LOG_PROC | Call by reference | Type reference (TYPE) | BALLOGHNDL | Application Log: Log handle | 20011123 | |||
| 3 | CV_LOG_TECH | Call by reference | Type reference (TYPE) | BALLOGHNDL | Application Log: Log handle | 20011123 | |||
| 4 | IV_ACTV | Call by reference | Type reference (TYPE) | CHAR10 | Character field length = 10 | 20011123 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | internal error | 20011123 |
Method IS_ACTIONS_BEFORE_BOTH Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CS_HEQUI | Call by reference | Type reference (TYPE) | V_EQUI | Generated Table for View V_EQUI | 20020508 | |||
| 2 | CS_HIFLO | Call by reference | Type reference (TYPE) | IFLO | Generated Table for View IFLO | 20020508 | |||
| 3 | CS_IPW4_COM | Call by reference | Type reference (TYPE) | IPW4_COM | Communication structure for Equipment install/removal trans. | 20020508 | |||
| 4 | CS_MVT_HEADER | Call by reference | Type reference (TYPE) | BAPI2017_GM_HEAD_01 | BAPI Communication Structure: Material Document Header Data | 20020508 | |||
| 5 | CS_MVT_ITEM | Call by reference | Type reference (TYPE) | BAPI2017_GM_ITEM_CREATE | BAPI Communication Structure: Create Material Document Item | 20020508 | |||
| 6 | CS_NOTIF_HEADER | Call by reference | Type reference (TYPE) | RIQS5 | PM/SM/QM Notifications: I/O data for creating notification | 20020508 | |||
| 7 | CS_SEQUI | Call by reference | Type reference (TYPE) | V_EQUI | Generated Table for View V_EQUI | 20020508 | |||
| 8 | CV_LOG_HANDLE | Call by reference | Type reference (TYPE) | BALLOGHNDL | Application Log: Log handle | 20020508 | |||
| 9 | CV_LOG_PROC_HANDLE | Call by reference | Type reference (TYPE) | BALLOGHNDL | Application Log: Log handle | 20030320 |
Method IS_ACTIONS_BEFORE_BOTH on class IF_EX_IERI_IPW4_INTERNAL1 has no exception.
Method SWITCH_SERNR_CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IV_MATNR | Call by reference | Type reference (TYPE) | MATNR | Material Number | 20011115 | |||
| 2 | IV_SERNR | Call by reference | Type reference (TYPE) | GERNR | Serial number | 20011115 | |||
| 3 | RV_MVMT_ALLOWED | Value transfer | Type reference (TYPE) | CHAR1 | 'X' : Movement for Serialnr allowed | 20011115 |
Method SWITCH_SERNR_CHECK on class IF_EX_IERI_IPW4_INTERNAL1 has no exception.
Method UPDATE_RESERVATION Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CS_ITOB | Call by reference | Type reference (TYPE) | ITOB | Generated Table for View ITOB | 20030509 | |||
| 2 | CS_MSEG | Call by reference | Type reference (TYPE) | MSEG | Document Segment: Material | 20030509 | |||
| 3 | CV_EQUNR | Call by reference | Type reference (TYPE) | EQUNR | Equipment number | 20030509 | |||
| 4 | ET_RETURN | Call by reference | Type reference (TYPE) | BAPIRETTAB | Tabelle mit BAPI Return Informationen | 20091203 | |||
| 5 | IS_IPW4_COM | Call by reference | Type reference (TYPE) | IPW4_COM | Communication structure for Equipment install/removal trans. | 20030509 | |||
| 6 | IV_MVMT_MODE | Call by reference | Type reference (TYPE) | CHAR1 | Single-character flag | 20030509 |
Method UPDATE_RESERVATION on class IF_EX_IERI_IPW4_INTERNAL1 has no exception.
History
| Last changed by/on | SAP | 20100310 |
| SAP Release Created in |