SAP ABAP Class IF_EX_EHSS_WWI_BADI_001 (BAdI Interface IF_EX_EHSS_WWI_BADI_001)
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_EHSS_WWI_BADI_001 | BAdI Class CL_EX_EHSS_WWI_BADI_001 | 20030306 |
Properties
| Class | IF_EX_EHSS_WWI_BADI_001 | |
| Short Description | BAdI Interface IF_EX_EHSS_WWI_BADI_001 | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 1 | |
| Package | ||
| Created | 20030305 | SAP |
| Last change | 20030306 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class IF_EX_EHSS_WWI_BADI_001 has no interface implemented.
Friends
Class IF_EX_EHSS_WWI_BADI_001 has no friend class.
Attributes
Class IF_EX_EHSS_WWI_BADI_001 has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Event on Buttons | 20030305 | |
| 2 | Instance method | Public | Method | Capture Event on Tab Page | 20030305 | |
| 3 | Instance method | Public | Method | Initializes the BAdI Object | 20030305 | |
| 4 | Instance method | Public | Method | Event --> Read from Word Document | 20030310 | |
| 5 | Instance method | Public | Method | Evaluate Event in Symbol Tree | 20030310 |
Events
Class IF_EX_EHSS_WWI_BADI_001 has no event.
Types
Class IF_EX_EHSS_WWI_BADI_001 has no local type.
Method Signatures
Method C12LAYOUT_ACTION Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_RESULT_OK | Call by reference | Type reference (TYPE) | ESP1_BOOLEAN | Wenn True dann badi ausgeführt | 20030310 | |||
| 2 | I_ACTIVE_TAB_INDEX | Call by reference | Type reference (TYPE) | I | Register index (i = 1) | 20030306 | |||
| 3 | I_DOCUMENT | Call by reference | Object reference (TYPE REF TO) | I_OI_DOCUMENT_PROXY | allgemeine Dokument-Schnittstelle | 20030306 | |||
| 4 | I_OK_CODE | Call by reference | Type reference (TYPE) | SY-UCOMM | OK_code drucktaste | 20030306 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | interner Fehler | 20030305 |
Method C12LAYOUT_ACTIVATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_DYNPRO_NR | Call by reference | Type reference (TYPE) | SY-DYNNR | ABAP-Programm, Nummer des aktuellen Dynpros | 20030306 | |||
| 2 | E_PROG_NAME | Call by reference | Type reference (TYPE) | SY-REPID | ABAP-Programm, Name des Programms | 20030306 | |||
| 3 | I_OK_CODE | Call by reference | Type reference (TYPE) | SY-UCOMM | Tab okcode | 20030306 | |||
| 4 | I_SELECTED_NODE | Call by reference | Type reference (TYPE) | RCGWWITREEITEMS | EHS: Struktur für die Knoten des Simple Treeviews | 20030306 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | interner Fehler | 20030305 |
Method C12LAYOUT_INIT Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_REGISTER_TAB | Call by reference | Type reference (TYPE) | RCGWWIBADIREGISTER_TAB_TYPE | EHS: Struktur für Badi Register | 20030306 | |||
| 2 | I_EDIT_MODE | Call by reference | Type reference (TYPE) | CHAR01 | 'E' | Edit, Exchange oder Displaymode | 20030306 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | interner Fehler | 20030305 |
Method C12LAYOUT_SYNCRO_DOC Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_RESULT_OK | Call by reference | Type reference (TYPE) | ESP1_BOOLEAN | Wenn Badi das Symbol erfolgreich identifiziertt hat = true | 20030310 | |||
| 2 | E_TAB_INDEX | Call by reference | Type reference (TYPE) | I | Badi Register index | 20030310 | |||
| 3 | I_SELECTED_SYMBOL | Call by reference | Type reference (TYPE) | STRING | Selektion im Worddokument | 20030310 |
Method C12LAYOUT_SYNCRO_DOC on class IF_EX_EHSS_WWI_BADI_001 has no exception.
Method C12LAYOUT_SYNCRO_TREE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_RESULT_OK | Call by reference | Type reference (TYPE) | ESP1_BOOLEAN | Ergebnis von BADI: true = Symbol in eigenen Register geladen | 20030310 | |||
| 2 | E_TAB_INDEX | Call by reference | Type reference (TYPE) | I | Wenn oberes flag true dann wird index des Tabreites gesetzt | 20030310 | |||
| 3 | I_SELECTED_SYMBOL | Call by reference | Type reference (TYPE) | RCGWWITREEITEMS | EHS: Struktur für die Knoten des Simple Treeviews | 20030310 |
Method C12LAYOUT_SYNCRO_TREE on class IF_EX_EHSS_WWI_BADI_001 has no exception.
History
| Last changed by/on | SAP | 20030306 |
| SAP Release Created in |