SAP ABAP Class IF_EX_EHSI_ACPM_DATA_TRANS (BAdI Interface IF_EX_EHSI_ACPM_DATA_TRANS)
Meta Relationship - Using
| # | Relationship type | Using | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface composition (i COMPRISING i_ref) | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20050908 |
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_DEF_IM_EHSI_ACPM_DATA_TRANS | Default Implementation for BAdI Definition EHSI_ACPM_DATA_TR | 20050907 |
Properties
| Class | IF_EX_EHSI_ACPM_DATA_TRANS | |
| Short Description | BAdI Interface IF_EX_EHSI_ACPM_DATA_TRANS | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | ||
| Created | 20050907 | SAP |
| Last change | 20100310 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 2 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class IF_EX_EHSI_ACPM_DATA_TRANS has no interface implemented.
Friends
Class IF_EX_EHSI_ACPM_DATA_TRANS has no friend class.
Attributes
Class IF_EX_EHSI_ACPM_DATA_TRANS has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Create Notification from IHS Safety Measure Screen | 20050907 | |
| 2 | Instance method | Public | Method | Read Back Notification Data to IH Safety Measures | 20050907 |
Events
Class IF_EX_EHSI_ACPM_DATA_TRANS has no event.
Types
Class IF_EX_EHSI_ACPM_DATA_TRANS has no local type.
Method Signatures
Method NOTIFICATION_CREATE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_FLG_CHANGED | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | falls TRUE: anzeigerelevante Änderung aus PM | 20050907 | |||
| 2 | E_FLG_NO_AUTHORITY | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | falls TRUE: keine Berechtigung für die gewünschte Aktion | 20050907 | |||
| 3 | E_FLG_SAVE_PEND | Value transfer | Type reference (TYPE) | ESP1_BOOLEAN | falls TRUE: Änderung in EH&S-Puffer aus PM | 20050907 | |||
| 4 | E_OKCODE | Value transfer | Type reference (TYPE) | ESP1_OKCODE_TYPE | Funktionscode | 20050907 | |||
| 5 | I_ACTION_LTXT_TAB | Call by reference | Type reference (TYPE) | CIHAC_ACLTAPI_TAB_TYPE | Langtext zur Maßnahme | 20050907 | |||
| 6 | I_ADDINF | Call by reference | Type reference (TYPE) | RCGADDINF | EHS: Zusatzinfos für FB-Aufrufe | 20050907 | |||
| 7 | I_KEYPATH | Call by reference | Type reference (TYPE) | CCIHS_ACREFOBJKPATH | EHS: "Schlüssel-Pfad" Referenzobjekt zur Maßnahmenliste | 20050907 | |||
| 8 | I_OKCODE | Call by reference | Type reference (TYPE) | ESP1_OKCODE_TYPE | Funktionscode | 20050907 | |||
| 9 | I_POPUP_DIALCTR | Call by reference | Type reference (TYPE) | RCGDIALCTR | PP-SHE: Dialogkontrollstruktur | 20050907 | |||
| 10 | X_ACTION_IOTAB | Call by reference | Type reference (TYPE) | CCIHY_ACHIOT | EHS: Tabellentyp für Arbeitschutzmaßnahmen | 20050907 |
Method NOTIFICATION_CREATE on class IF_EX_EHSI_ACPM_DATA_TRANS has no exception.
Method NOTIFICATION_READBACK Signature
Method NOTIFICATION_READBACK on class IF_EX_EHSI_ACPM_DATA_TRANS has no parameter.
Method NOTIFICATION_READBACK on class IF_EX_EHSI_ACPM_DATA_TRANS has no exception.
History
| Last changed by/on | SAP | 20100310 |
| SAP Release Created in |