SAP ABAP Class IF_EX_EHS_PS_001 (BAdI Interface IF_EX_EHS_PS_001)
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_DEF_IM_EHS_PS_001 | Default Implementation for BAdI Definition EHS_PS_001 | 20010703 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_EHS_PS_001 | BAdI-Klasse CL_EX_EHS_PS_001 | 20010703 |
Properties
| Class | IF_EX_EHS_PS_001 | |
| Short Description | BAdI Interface IF_EX_EHS_PS_001 | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 1 | |
| Package | ||
| Created | 20010703 | SAP |
| Last change | 00000000 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
Class IF_EX_EHS_PS_001 has no forward declaration.
Interfaces
Class IF_EX_EHS_PS_001 has no interface implemented.
Friends
Class IF_EX_EHS_PS_001 has no friend class.
Attributes
Class IF_EX_EHS_PS_001 has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | (See C10G_AENNR_CHANGE in PLM Add-On) | 20010703 | |
| 2 | Instance method | Public | Method | (See C11G_AENNR_CHANGE in PLM Add-On) | 20010703 | |
| 3 | Instance method | Public | Method | (See C10G_AENNR_CHECK in PLM Add-On) | 20010703 | |
| 4 | Instance method | Public | Method | (See C11G_AENNR_CHECK in PLM Add-On) | 20010703 | |
| 5 | Instance method | Public | Method | (See C10G_AENNR_SHOW in PLM Add-On) | 20010703 | |
| 6 | Instance method | Public | Method | (See C11G_AENNR_SHOW in PLM Add-On) | 20010703 | |
| 7 | Instance method | Public | Method | (See C10G_AENNR_USE in PLM Add-On) | 20010703 | |
| 8 | Instance method | Public | Method | (See C11G_AENNR_USE in PLM Add-On) | 20010703 | |
| 9 | Instance method | Public | Method | List for Report RC1A2NNR (in PLM Add-On) to Memory | 20010704 | |
| 10 | Instance method | Public | Method | List for Report RC1AENNR (in PLM Add-On) to Memory | 20010704 | |
| 11 | Instance method | Public | Method | Report for Change Number Where-Used List 'Substance' | 20010704 | |
| 12 | Instance method | Public | Method | Report for Change Number Where-Used List 'Phrase' | 20010704 |
Events
Class IF_EX_EHS_PS_001 has no event.
Types
Class IF_EX_EHS_PS_001 has no local type.
Method Signatures
Method AENNR_CHANGE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_AENNR | Value transfer | Type reference (TYPE) | AENR-AENNR | Änderungsnummer | 20010703 | |||
| 2 | I_DATUV | Value transfer | Type reference (TYPE) | SY-DATUM | Datum und Zeit, aktuelles (Applikationsserver-)Datum | 20010703 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | interner Fehler | 20010703 |
Method AENNR_CHANGE2 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_AENNR | Value transfer | Type reference (TYPE) | AENR-AENNR | Änderungsnummer | 20010703 | |||
| 2 | I_DATUV | Value transfer | Type reference (TYPE) | SY-DATUM | Datum und Zeit, aktuelles (Applikationsserver-)Datum | 20010703 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | interner Fehler | 20010703 |
Method AENNR_CHECK Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_AENNR | Value transfer | Type reference (TYPE) | AENR-AENNR | Änderungsnummer | 20010703 | |||
| 2 | I_DATUV | Value transfer | Type reference (TYPE) | SY-DATUM | Datum und Zeit, aktuelles (Applikationsserver-)Datum | 20010703 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | eine angeforderte Sperre wurde nicht gewährt | 20010703 | ||
| 2 | interner Fehler | 20010703 | ||
| 3 | neues Datum der Änderungsnummer ist zu klein | 20010703 | ||
| 4 | neues Datum der Änderungsnummer ist zu groß | 20010703 |
Method AENNR_CHECK2 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_AENNR | Value transfer | Type reference (TYPE) | AENR-AENNR | Änderungsnummer | 20010703 | |||
| 2 | I_DATUV | Value transfer | Type reference (TYPE) | SY-DATUM | Datum und Zeit, aktuelles (Applikationsserver-)Datum | 20010703 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | eine angeforderte Sperre wurde nicht gewährt | 20010703 | ||
| 2 | interner Fehler | 20010703 | ||
| 3 | neues Datum der Änderungsnummer ist zu klein | 20010703 | ||
| 4 | neues Datum der Änderungsnummer ist zu groß | 20010703 |
Method AENNR_SHOW Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_AENNR | Value transfer | Type reference (TYPE) | AENR-AENNR | Änderungsnummer | 20010703 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | interner Fehler | 20010703 |
Method AENNR_SHOW2 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_AENNR | Value transfer | Type reference (TYPE) | AENR-AENNR | Änderungsnummer | 20010703 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | interner Fehler | 20010703 |
Method AENNR_USE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_USEFLG | Value transfer | Type reference (TYPE) | ANY | ist 'X', wenn Änderungsnummer verwendet wird | 20010703 | |||
| 2 | I_AENNR | Value transfer | Type reference (TYPE) | AENR-AENNR | Änderungsnummer | 20010703 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | interner Fehler | 20010703 |
Method AENNR_USE2 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_USEFLG | Value transfer | Type reference (TYPE) | ANY | ist 'X', wenn Änderungsnummer verwendet wird | 20010703 | |||
| 2 | I_AENNR | Value transfer | Type reference (TYPE) | AENR-AENNR | Änderungsnummer | 20010703 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | interner Fehler | 20010703 |
Method RC1A2NNR_LIST_TO_MEMORY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_AENNR | Value transfer | Type reference (TYPE) | AENR-AENNR | Änderungsnummer | 20010704 |
Method RC1A2NNR_LIST_TO_MEMORY on class IF_EX_EHS_PS_001 has no exception.
Method RC1AENNR_LIST_TO_MEMORY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_AENNR | Value transfer | Type reference (TYPE) | AENR-AENNR | Änderungsnummer | 20010704 |
Method RC1AENNR_LIST_TO_MEMORY on class IF_EX_EHS_PS_001 has no exception.
Method REPID_GET Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_REPID | Value transfer | Type reference (TYPE) | SY-REPID | 20010704 |
Method REPID_GET on class IF_EX_EHS_PS_001 has no exception.
Method REPID_GET2 Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_REPID | Value transfer | Type reference (TYPE) | SY-REPID | 20010704 |
Method REPID_GET2 on class IF_EX_EHS_PS_001 has no exception.
History
| Last changed by/on | SAP | 00000000 |
| SAP Release Created in |