SAP ABAP Class IF_EX_ECM (BAdI Interface IF_EX_ECM)
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EXM_IM_ECM | BAdI Definition for ECM: Sample Implementations | 20020624 |
| 2 | Interface implementation (CLASS c. INTERFACES i_ref) | CL_EX_ECM | BAdI Class CL_EX_ECM | 20020624 |
Properties
| Class | IF_EX_ECM | |
| Short Description | BAdI Interface IF_EX_ECM | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 1 | |
| Package | ||
| Created | 20020624 | SAP |
| Last change | 20040518 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
Class IF_EX_ECM has no forward declaration.
Interfaces
Class IF_EX_ECM has no interface implemented.
Friends
Class IF_EX_ECM has no friend class.
Attributes
Class IF_EX_ECM has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Static method | Public | Method | Change Graph: New Status | 20020725 | |
| 2 | Static method | Public | Method | Engineering Change Order: Additional Authorization Check | 20020701 | |
| 3 | Static method | Public | Method | Engineering Change Order: Before Saving | 20020701 | |
| 4 | Static method | Public | Method | Validity: Additional Authorization Check | 20020624 | |
| 5 | Static method | Public | Method | Validity: Change | 20020624 | |
| 6 | Static method | Public | Method | Validity: Continuity Check | 20020624 | |
| 7 | Static method | Public | Method | Validity: Before Saving | 20020624 |
Events
Class IF_EX_ECM has no event.
Types
Class IF_EX_ECM has no local type.
Method Signatures
Method CHANGE_GRAPH_NEW Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_NEW_GRAPH | Value transfer | Type reference (TYPE) | FLAG | Graph wird gerade angelegt | 20020725 | |||
| 2 | I_OBJECT_GUID | Value transfer | Type reference (TYPE) | ECMOBJGUID | GUID Objekt | 20020725 | |||
| 3 | I_OBJECT_TYPE | Value transfer | Type reference (TYPE) | ECMOTYP | Objekttyp | 20020725 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Objekt kann nicht gesperrt werden | 20020725 | ||
| 2 | Sonstiger Fehler | 20020725 |
Method ORDER_AUTHORITY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_ACTIVITY | Value transfer | Type reference (TYPE) | ECMAUTH | gewünschte Aktivität | 20020701 | |||
| 2 | I_ORDER_GUID | Value transfer | Type reference (TYPE) | ECMORDGUID | GUID Änderungsauftrag | 20020701 | |||
| 3 | I_ORDER_INST | Value transfer | Type reference (TYPE) | ECMORD | Änderungsauftrag | 20020701 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Berechtigung fehlt (siehe Meldung in SYST!) | 20020701 |
Method ORDER_SAVE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CS_ECMORD | Value transfer | Type reference (TYPE) | ECM_ORD | Änderungsauftrag | 20021216 | |||
| 2 | CS_ECM_USERADM | Value transfer | Type reference (TYPE) | ECM_ADM | Administrationsdaten | 20021216 | |||
| 3 | CT_ECMHIE | Value transfer | Type reference (TYPE) | TTADMECMHIEX | Tabelle zur Verwaltung der Hierarchieinformationen ECM | 20021216 | |||
| 4 | CT_ECMSTXT | Value transfer | Type reference (TYPE) | TTECMSTXTX | Tabelle zum Kurztext | 20021216 | |||
| 5 | CT_OBJADM | Value transfer | Type reference (TYPE) | TTECMOBJADMX | Tabellentyp von Struktur ECM_OBJADM | 20021216 |
Method ORDER_SAVE on class IF_EX_ECM has no exception.
Method VALIDITY_AUTHORITY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_ACTIVITY | Value transfer | Type reference (TYPE) | ECMAUTH | Bearbeitungsart | 20020624 | |||
| 2 | I_CONTEXT | Value transfer | Type reference (TYPE) | ECMCTXT | Kontext | 20020624 | |||
| 3 | I_CONTEXT_GUID | Value transfer | Type reference (TYPE) | ECMCTXTGUID | GUID Kontext | 20020624 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Berechtigung fehlt (siehe Meldung in SYST!) | 20020624 |
Method VALIDITY_CHECK_CHANGE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IT_VALIDITY_NEW | Value transfer | Type reference (TYPE) | TT_ECM_VAL_EXT | neue Gültigkeit | 20020624 | |||
| 2 | IT_VALIDITY_OLD | Value transfer | Type reference (TYPE) | TT_ECM_VAL_EXT | alte Gültigkeit | 20020624 | |||
| 3 | I_CHANGE_KIND | Value transfer | Type reference (TYPE) | ECMKND | Änderungsart | 20020624 | |||
| 4 | I_ORDER_GUID | Value transfer | Type reference (TYPE) | ECMORDGUID | GUID Änderungsauftrag | 20020624 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Gültigkeitaänderung nicht zulässig (siehe Meldung in SYST!) | 20020624 |
Method VALIDITY_CHECK_STEADY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IT_OBJECT_ADM | Value transfer | Type reference (TYPE) | TTECMOBJADM | Objektverwaltungssätze | 20020624 | |||
| 2 | IT_VALIDITY | Value transfer | Type reference (TYPE) | TT_ECM_VAL_EXT | Gültigkeiten | 20020624 | |||
| 3 | I_ECM_GUID | Value transfer | Type reference (TYPE) | ECMORDGUID | GUID zu prüfender Änderungsauftrag | 20020624 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Gewünschte Gültigkeit nicht stetig (siehe Meldung in SYST!) | 20020624 |
Method VALIDITY_SAVE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CT_VALIDITY | Value transfer | Type reference (TYPE) | TT_ECM_VAL_EXT | Gültigkeiten zu Instanz | 20020624 | |||
| 2 | I_CHANGE_KIND | Value transfer | Type reference (TYPE) | ECMKND | Änderungsart | 20020624 | |||
| 3 | I_ORDER_GUID | Value transfer | Type reference (TYPE) | ECMORDGUID | GUID Änderungsauftrag | 20020624 |
Method VALIDITY_SAVE on class IF_EX_ECM has no exception.
History
| Last changed by/on | SAP | 20040518 |
| SAP Release Created in |