SAP ABAP Class IF_EX_BADI_WCM_WAPI_001_SAP (Interface for BAdI: BADI_WCM_WAPI_001_SAP)
Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Interface composition (i COMPRISING i_ref) | IF_BADI_INTERFACE | Tag Interface for BAdIs | 20120914 |
Properties
Class | IF_EX_BADI_WCM_WAPI_001_SAP | |
Short Description | Interface for BAdI: BADI_WCM_WAPI_001_SAP | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | ||
Created | 20120914 | SAP |
Last change | 20130531 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class IF_EX_BADI_WCM_WAPI_001_SAP has no interface implemented.
Friends
Class IF_EX_BADI_WCM_WAPI_001_SAP has no friend class.
Attributes
Class IF_EX_BADI_WCM_WAPI_001_SAP has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Specify Name of SAP-Internal Append Structure | 20120914 |
2 | ![]() |
Instance method | Public | Method | Transport Data from Subscreen | 20120914 |
3 | ![]() |
Instance method | Public | Method | Transport Data to Subscreen | 20120914 |
4 | ![]() |
Instance method | Public | Method | Execute Function Code | 20120914 |
Events
Class IF_EX_BADI_WCM_WAPI_001_SAP has no event.
Types
Class IF_EX_BADI_WCM_WAPI_001_SAP has no local type.
Method Signatures
Method APPEND_NAME_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_APPEND_NAME | Value transfer | Type reference (TYPE) | DDOBJNAME | Name der Append-Struktur | 20120914 | ||
2 | ![]() |
IV_DYNFLDGRP | Value transfer | Type reference (TYPE) | WCEDYNFLDGRP | Gruppierung von Subscreen-Feldern | 20120914 | ||
3 | ![]() |
IV_SCREEN | Value transfer | Type reference (TYPE) | SYDYNNR | Aktuelle Dynpro-Nummer | 20120914 |
Method APPEND_NAME_GET on class IF_EX_BADI_WCM_WAPI_001_SAP has no exception.
Method SUBSCREEN_DATA_GET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ES_WAPI | Value transfer | Type reference (TYPE) | WCSWAPI | Struktur: Anforderung | 20120914 | ||
2 | ![]() |
IV_SCREEN | Value transfer | Type reference (TYPE) | SYDYNNR | Aktuelle Dynpro-Nummer | 20120914 |
Method SUBSCREEN_DATA_GET on class IF_EX_BADI_WCM_WAPI_001_SAP has no exception.
Method SUBSCREEN_DATA_SET Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IS_WAPI | Value transfer | Type reference (TYPE) | WCSWAPI | Struktur: Anforderung | 20120914 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120914 | ||
3 | ![]() |
IV_DYNFLDGRP | Value transfer | Type reference (TYPE) | WCEDYNFLDGRP | Gruppierung von Subscreen-Feldern | 20120914 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120914 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120914 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120914 | ||
7 | ![]() |
IV_SCREEN | Value transfer | Type reference (TYPE) | SYDYNNR | Aktuelle Dynpro-Nummer | 20120914 |
Method SUBSCREEN_DATA_SET on class IF_EX_BADI_WCM_WAPI_001_SAP has no exception.
Method SUBSCREEN_FCODE_EXECUTE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
EV_PROCESSED | Value transfer | Type reference (TYPE) | WCEBOOLEAN | 1 := Verarbeitung ist erfolgt | 20120914 | ||
2 | ![]() |
IV_AKTYP | Value transfer | Type reference (TYPE) | AKTYP | Aktivitätstyp | 20120914 | ||
3 | ![]() |
IV_FCODE | Value transfer | Type reference (TYPE) | WCTPF_FCODE_TYPE | Funktionscode | 20120914 | ||
4 | ![]() |
IV_IWERK | Value transfer | Type reference (TYPE) | IWERK | Planungswerk | 20120914 | ||
5 | ![]() |
IV_OBJNR | Value transfer | Type reference (TYPE) | J_OBJNR | Objektnummer | 20120914 | ||
6 | ![]() |
IV_OBJTYP | Value transfer | Type reference (TYPE) | WCETYP | Subobjektart | 20120914 | ||
7 | ![]() |
IV_SCREEN | Value transfer | Type reference (TYPE) | SYDYNNR | Aktuelle Dynpro-Nummer | 20120914 |
Method SUBSCREEN_FCODE_EXECUTE on class IF_EX_BADI_WCM_WAPI_001_SAP has no exception.
History
Last changed by/on | SAP | 20130531 |
SAP Release Created in |