SAP ABAP Class CL_WDR_ACTIVE_COMP_LIFECYLCE (Lifespan Administration of Active Components)
Hierarchy
☛
SAP_UI (Software Component) User Interface Technology
⤷
BC-WD-ABA-REN (Application Component) Web Dynpro ABAP Rendering
⤷
SWDP_RUNTIME_RENDERING (Package) Web Dynpro Runtime: Rendering

⤷

⤷

Properties
Class | CL_WDR_ACTIVE_COMP_LIFECYLCE | |
Short Description | Lifespan Administration of Active Components | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | SWDP_RUNTIME_RENDERING | Web Dynpro Runtime: Rendering |
Created | 20100421 | SAP |
Last change | 20131127 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_WDR_ACTIVE_COMP_LIFECYLCE has no interface implemented.
Friends
Class CL_WDR_ACTIVE_COMP_LIFECYLCE has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
Instance attribute | Private | Type reference (TYPE) | TT_ACTIVE_COMPONENTS | 20101008 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Method | Adds a sleeping Active Component | 20101008 |
2 | ![]() |
Instance method | Public | Method | Closing of Orphaned Sleeping Active Components | 20100421 |
3 | ![]() |
Instance method | Public | Method | Closing of Active Component | 20100421 |
4 | ![]() |
Instance method | Public | Method | Closing of Active Component | 20101008 |
5 | ![]() |
Instance method | Public | Method | Returns a sleeping Active Component | 20101008 |
6 | ![]() |
Instance method | Public | Method | Returns all sleeping Active Components (trace) | 20101008 |
7 | ![]() |
Instance method | Public | Method | Checks whether the lifespan of an active comp is whenAlive | 20101008 |
8 | ![]() |
Instance method | Public | Method | Adds a sleeping Active Component | 20101008 |
Events
Class CL_WDR_ACTIVE_COMP_LIFECYLCE has no event.
Types
# | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
---|---|---|---|---|---|---|---|
1 | TT_ACTIVE_COMPONENTS | Public | See coding | 20101008 | tt_active_components type hashed table of t_active_component with unique key view_element_adapter context_element
|
||
2 | T_ACTIVE_COMPONENT | Public | See coding | 20130423 | begin of t_active_component,
view_element_adapter type ref to cl_nw7_view_element_adapter,
context_element type ref to if_wd_context_element,
end of t_active_component
|
Method Signatures
Method ADD_ACTIVE_COMPONENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ACTIVE_COMPONENT | Call by reference | Object reference (TYPE REF TO) | CL_NW7_VIEW_ELEMENT_ADAPTER | WebDynpro Local Test XX7 | 20101008 | ||
2 | ![]() |
CONTEXT_ELEMENT | Call by reference | Object reference (TYPE REF TO) | IF_WD_CONTEXT_ELEMENT | Web Dynpro: Schnittstelle für ein Knotenelement | 20130423 |
Method ADD_ACTIVE_COMPONENT on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.
Method CLEAN_SLEEPING Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CLIENT_COMMAND_QUEUE | Call by reference | Object reference (TYPE REF TO) | IF_WDR_CLIENT_COMMAND | Kommando für den Client (UPDATE) | 20100421 |
Method CLEAN_SLEEPING on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.
Method DESTROY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CLIENT_COMMAND_QUEUE | Call by reference | Object reference (TYPE REF TO) | IF_WDR_CLIENT_COMMAND | Kommando für den Client (UPDATE) | 20100421 | ||
2 | ![]() |
CONTEXT_ELEMENT | Call by reference | Object reference (TYPE REF TO) | IF_WD_CONTEXT_ELEMENT | Web Dynpro: Schnittstelle für ein Knotenelement | 20130423 | ||
3 | ![]() |
VIEW_ELEMENT_ADAPTER | Call by reference | Object reference (TYPE REF TO) | CL_NW7_VIEW_ELEMENT_ADAPTER | WebDynpro Local Test XX7 | 20100421 |
Method DESTROY on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.
Method FINALIZE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
CLIENT_COMMAND_QUEUE | Call by reference | Object reference (TYPE REF TO) | IF_WDR_CLIENT_COMMAND | Kommando für den Client (UPDATE) | 20101008 | ||
2 | ![]() |
CONTEXT_ELEMENT | Call by reference | Object reference (TYPE REF TO) | IF_WD_CONTEXT_ELEMENT | Web Dynpro: Schnittstelle für ein Knotenelement | 20130423 | ||
3 | ![]() |
VIEW_ELEMENT_ADAPTER | Call by reference | Object reference (TYPE REF TO) | CL_NW7_VIEW_ELEMENT_ADAPTER | WebDynpro Local Test XX7 | 20101008 |
Method FINALIZE on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.
Method GET_ACTIVE_COMPONENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ACTIVE_COMPONENT | Value transfer | Object reference (TYPE REF TO) | CL_NW7_VIEW_ELEMENT_ADAPTER | WebDynpro Local Test XX7 | 20101008 | ||
2 | ![]() |
CONTEXT_ELEMENT | Call by reference | Object reference (TYPE REF TO) | IF_WD_CONTEXT_ELEMENT | Web Dynpro: Schnittstelle für ein Knotenelement | 20130423 | ||
3 | ![]() |
VIEW_ELEMENT | Call by reference | Object reference (TYPE REF TO) | CL_WDR_VIEW_ELEMENT | WebDynpro View Element | 20101008 |
Method GET_ACTIVE_COMPONENT on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.
Method GET_ALL_ACTIVE_COMPONENTS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
SLEEPING_ACTIVE_COMPONENTS | Value transfer | Type reference (TYPE) | TT_ACTIVE_COMPONENTS | 20101008 |
Method GET_ALL_ACTIVE_COMPONENTS on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.
Method IS_LIFETIME_WHEN_ALIVE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IS_WHEN_ALIVE | Value transfer | Type reference (TYPE) | ABAP_BOOL | 20101008 | |||
2 | ![]() |
VIEW_ELEMENT | Call by reference | Object reference (TYPE REF TO) | CL_WDR_VIEW_ELEMENT | WebDynpro View Element | 20101008 |
Method IS_LIFETIME_WHEN_ALIVE on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.
Method REMOVE_ACTIVE_COMPONENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ACTIVE_COMPONENT | Call by reference | Object reference (TYPE REF TO) | CL_NW7_VIEW_ELEMENT_ADAPTER | WebDynpro Local Test XX7 | 20101008 | ||
2 | ![]() |
CONTEXT_ELEMENT | Call by reference | Object reference (TYPE REF TO) | IF_WD_CONTEXT_ELEMENT | Web Dynpro: Schnittstelle für ein Knotenelement | 20130423 |
Method REMOVE_ACTIVE_COMPONENT on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.
History
Last changed by/on | SAP | 20131127 |
SAP Release Created in | 703 |