SAP ABAP Class CL_WDR_ACTIVE_COMP_LIFECYLCE (Lifespan Administration of Active Components)
Hierarchy
SAP_UI (Software Component) User Interface Technology
   BC-WD-ABA-REN (Application Component) Web Dynpro ABAP Rendering
     SWDP_RUNTIME_RENDERING (Package) Web Dynpro Runtime: Rendering
Properties
Class CL_WDR_ACTIVE_COMP_LIFECYLCE  
Short Description Lifespan Administration of Active Components    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package SWDP_RUNTIME_RENDERING   Web Dynpro Runtime: Rendering 
Created 20100421   SAP 
Last change 20131127   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ABAP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Class CL_WDR_ACTIVE_COMP_LIFECYLCE has no interface implemented.
Friends
Class CL_WDR_ACTIVE_COMP_LIFECYLCE has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 MT_ACTIVE_COMPONENTS Instance attribute Private Type reference (TYPE) TT_ACTIVE_COMPONENTS 20101008
Methods
# Method Level Visibility Method type Description Created on
1 ADD_ACTIVE_COMPONENT Instance method Public Method Adds a sleeping Active Component 20101008
2 CLEAN_SLEEPING Instance method Public Method Closing of Orphaned Sleeping Active Components 20100421
3 DESTROY Instance method Public Method Closing of Active Component 20100421
4 FINALIZE Instance method Public Method Closing of Active Component 20101008
5 GET_ACTIVE_COMPONENT Instance method Public Method Returns a sleeping Active Component 20101008
6 GET_ALL_ACTIVE_COMPONENTS Instance method Public Method Returns all sleeping Active Components (trace) 20101008
7 IS_LIFETIME_WHEN_ALIVE Instance method Public Method Checks whether the lifespan of an active comp is whenAlive 20101008
8 REMOVE_ACTIVE_COMPONENT Instance method Public Method Adds a sleeping Active Component 20101008
Events
Class CL_WDR_ACTIVE_COMP_LIFECYLCE has no event.
Types
# Type Visibility Typing Associated Type Description Created on Type Source
1 TT_ACTIVE_COMPONENTS Public See coding 20101008 tt_active_components type hashed table of t_active_component with unique key view_element_adapter context_element
2 T_ACTIVE_COMPONENT Public See coding 20130423 begin of t_active_component, view_element_adapter type ref to cl_nw7_view_element_adapter, context_element type ref to if_wd_context_element, end of t_active_component
Method Signatures

Method ADD_ACTIVE_COMPONENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ACTIVE_COMPONENT Call by reference Object reference (TYPE REF TO) CL_NW7_VIEW_ELEMENT_ADAPTER WebDynpro Local Test XX7 20101008
2 Importing CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Schnittstelle für ein Knotenelement 20130423

Method ADD_ACTIVE_COMPONENT on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.

Method CLEAN_SLEEPING Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CLIENT_COMMAND_QUEUE Call by reference Object reference (TYPE REF TO) IF_WDR_CLIENT_COMMAND Kommando für den Client (UPDATE) 20100421

Method CLEAN_SLEEPING on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.

Method DESTROY Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CLIENT_COMMAND_QUEUE Call by reference Object reference (TYPE REF TO) IF_WDR_CLIENT_COMMAND Kommando für den Client (UPDATE) 20100421
2 Importing CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Schnittstelle für ein Knotenelement 20130423
3 Importing VIEW_ELEMENT_ADAPTER Call by reference Object reference (TYPE REF TO) CL_NW7_VIEW_ELEMENT_ADAPTER WebDynpro Local Test XX7 20100421

Method DESTROY on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.

Method FINALIZE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing CLIENT_COMMAND_QUEUE Call by reference Object reference (TYPE REF TO) IF_WDR_CLIENT_COMMAND Kommando für den Client (UPDATE) 20101008
2 Importing CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Schnittstelle für ein Knotenelement 20130423
3 Importing VIEW_ELEMENT_ADAPTER Call by reference Object reference (TYPE REF TO) CL_NW7_VIEW_ELEMENT_ADAPTER WebDynpro Local Test XX7 20101008

Method FINALIZE on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.

Method GET_ACTIVE_COMPONENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning ACTIVE_COMPONENT Value transfer Object reference (TYPE REF TO) CL_NW7_VIEW_ELEMENT_ADAPTER WebDynpro Local Test XX7 20101008
2 Importing CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Schnittstelle für ein Knotenelement 20130423
3 Importing VIEW_ELEMENT Call by reference Object reference (TYPE REF TO) CL_WDR_VIEW_ELEMENT WebDynpro View Element 20101008

Method GET_ACTIVE_COMPONENT on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.

Method GET_ALL_ACTIVE_COMPONENTS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning SLEEPING_ACTIVE_COMPONENTS Value transfer Type reference (TYPE) TT_ACTIVE_COMPONENTS 20101008

Method GET_ALL_ACTIVE_COMPONENTS on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.

Method IS_LIFETIME_WHEN_ALIVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning IS_WHEN_ALIVE Value transfer Type reference (TYPE) ABAP_BOOL 20101008
2 Importing VIEW_ELEMENT Call by reference Object reference (TYPE REF TO) CL_WDR_VIEW_ELEMENT WebDynpro View Element 20101008

Method IS_LIFETIME_WHEN_ALIVE on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.

Method REMOVE_ACTIVE_COMPONENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing ACTIVE_COMPONENT Call by reference Object reference (TYPE REF TO) CL_NW7_VIEW_ELEMENT_ADAPTER WebDynpro Local Test XX7 20101008
2 Importing CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Schnittstelle für ein Knotenelement 20130423

Method REMOVE_ACTIVE_COMPONENT on class CL_WDR_ACTIVE_COMP_LIFECYLCE has no exception.
History
Last changed by/on SAP  20131127 
SAP Release Created in 703