SAP ABAP Class CL_UC_MD_VALCHECK_FACTORY (CL_UC_MD_VALCHECK_FACTORY)
Hierarchy
☛
SEM-BW (Software Component) SEM-BW: Strategic Enterprise Management
⤷
FIN-SEM-BCS (Application Component) Business Consolidation
⤷
UCUW (Package) SEM-BCS: User Interface: Workbench
⤷
⤷
Meta Relationship - Using
| # | Relationship type | Using | Short Description | Created on |
|---|---|---|---|---|
| 1 | Inheritance (c INHERITING FROM c_ref) | CL_UG_MD_CHAR | FIN Master Data: Access to Data | 20031201 |
Properties
| Class | CL_UC_MD_VALCHECK_FACTORY | |
| Short Description | ||
| Super Class | CL_UG_MD_CHAR | FIN Master Data: Access to Data |
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | UCUW | SEM-BCS: User Interface: Workbench |
| Created | 20031201 | SAP |
| Last change | 20110810 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Forward declaration class (CLASS c DEFINITION DEFERRED) | Forward declaration class (CLASS c DEFINITION DEFERRED) | |
| 2 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_UC_MD_VALCHECK_FACTORY has no interface implemented.
Friends
Class CL_UC_MD_VALCHECK_FACTORY has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Constant | Private | Type reference (TYPE) | UG_FIELDNAME | 'VALCHECKID' | FIN Master Data: Field Name | 20031201 | ||
| 2 | Constant | Private | Type reference (TYPE) | UG_FIELDNAME | 'VALCHECK' | FIN Master Data: Field Name | 20031201 | ||
| 3 | Static Attribute | Private | Object reference (TYPE REF TO) | CL_UC_VALCHECK_FACTORY | 20031201 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | 20091110 | ||
| 2 | Static method | Public | Constructor | CLASS_CONSTRUCTOR | 20031201 | |
| 3 | Instance method | Public | Constructor | CONSTRUCTOR | 20031201 | |
| 4 | Instance method | Private | Method | 20031201 | ||
| 5 | Instance method | Private | Method | 20031201 | ||
| 6 | Instance method | Private | Method | 20031201 | ||
| 7 | Instance method | Private | Method | 20031201 | ||
| 8 | Instance method | Private | Method | 20040419 |
Events
Class CL_UC_MD_VALCHECK_FACTORY has no event.
Types
Class CL_UC_MD_VALCHECK_FACTORY has no local type.
Method Signatures
Method CHECK_AUTHORITY_P Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | CT_VALUE | Call by reference | Type reference (TYPE) | ANY TABLE | 20091110 | ||||
| 2 | ET_MESSAGE | Call by reference | Type reference (TYPE) | UGMD_T_MESSAGE | FI-Stammdaten: Meldungen | 20091110 | |||
| 3 | I_ACTVT | Value transfer | Type reference (TYPE) | AUTHB-ACTVT | Aktivität | 20091110 |
Method CHECK_AUTHORITY_P on class CL_UC_MD_VALCHECK_FACTORY has no exception.
Method CLASS_CONSTRUCTOR Signature
Method CLASS_CONSTRUCTOR on class CL_UC_MD_VALCHECK_FACTORY has no parameter.
Method CLASS_CONSTRUCTOR on class CL_UC_MD_VALCHECK_FACTORY has no exception.
Method CONSTRUCTOR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IO_FACTORY | Call by reference | Object reference (TYPE REF TO) | IF_UG_MD_FACTORY | FIN-Stammdaten: Zentraler Zugriffspunkt (Factory) | 20031201 | |||
| 2 | I_APPLICATION | Call by reference | Type reference (TYPE) | UG_APPLICATION | FI-Stammdaten: Anwendung | 20031201 | |||
| 3 | I_AREAID | Call by reference | Type reference (TYPE) | UG_AREAID | FIN-Stammdaten: Anwendungsgebiet | 20031201 | |||
| 4 | I_BUFFERED | Call by reference | Type reference (TYPE) | UG_FLG | FI-Stammdaten: Allgemeines Kennzeichen | 20031201 | |||
| 5 | I_FIELDNAME | Call by reference | Type reference (TYPE) | UG_FIELDNAME | FI-Stammdaten: Feldname | 20031201 |
Method CONSTRUCTOR on class CL_UC_MD_VALCHECK_FACTORY has no exception.
Method VC_CONVERT_GUID_TO_SEMKEY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_SEMKEY | Call by reference | Type reference (TYPE) | UC0_TS_VALUE | Feldwerte | 20031201 | |||
| 2 | I_GUID | Call by reference | Type reference (TYPE) | UC_CUST_GUID | GUID für Customizing SAP Konsolidierung | 20031201 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | 20031201 |
Method VC_GET_FIELDLIST_FOR_RW Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_FIELD | Call by reference | Type reference (TYPE) | UGMD_TS_FIELDNAME | FI-Stammdaten: Feldnamen | 20031201 | |||
| 2 | IT_FIELD | Call by reference | Type reference (TYPE) | UGMD_TS_FIELDNAME | FI-Stammdaten: Feldnamen | 20031201 | |||
| 3 | IT_ITAB | Call by reference | Type reference (TYPE) | ANY TABLE | 20031201 |
Method VC_GET_FIELDLIST_FOR_RW on class CL_UC_MD_VALCHECK_FACTORY has no exception.
Method VC_INIT_FPROP Signature
Method VC_INIT_FPROP on class CL_UC_MD_VALCHECK_FACTORY has no parameter.
Method VC_INIT_FPROP on class CL_UC_MD_VALCHECK_FACTORY has no exception.
Method VC_READ_VALUE_P Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_VALUE | Call by reference | Type reference (TYPE) | ANY TABLE | 20031201 | ||||
| 2 | IT_FIELD | Call by reference | Type reference (TYPE) | UGMD_TS_FIELDNAME | FI-Stammdaten: Feldnamen | 20031201 | |||
| 3 | IT_SEL | Call by reference | Type reference (TYPE) | UGMD_TS_SEL | Sortierte Tabelle: Selektionsbedingung (Range pro Feld) | 20031201 | |||
| 4 | I_FLAT_LINE_TYPE | Call by reference | Type reference (TYPE) | STRING | 20031201 |
Method VC_READ_VALUE_P on class CL_UC_MD_VALCHECK_FACTORY has no exception.
Method VC_WAS_DELETED_VALUE_REUSABLE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_NAME | Call by reference | Type reference (TYPE) | UGMD_TS_FIELD_VAL | FI-Stammdaten: Paare Feldname / Wert | 20040419 | |||
| 2 | E_IS_REUSABLE | Call by reference | Type reference (TYPE) | UG_FLG | FI-Stammdaten: Allgemeines Kennzeichen | 20040419 | |||
| 3 | E_TRUE_GUID | Call by reference | Type reference (TYPE) | UG_VALUE | Merkmalswert | 20040419 | |||
| 4 | I_GUID | Call by reference | Type reference (TYPE) | UG_VALUE | Merkmalswert | 20040419 |
Method VC_WAS_DELETED_VALUE_REUSABLE on class CL_UC_MD_VALCHECK_FACTORY has no exception.
History
| Last changed by/on | SAP | 20110810 |
| SAP Release Created in | 400 |