SAP ABAP Class CL_RSDRC_SELC_SRVS (Service(s) for SELC)
Hierarchy
☛
SAP_BW (Software Component) SAP Business Warehouse
⤷
BW-BEX-OT (Application Component) OLAP Technology
⤷
RSDRC (Package) Data Manager InfoProvider Read Access
⤷
⤷
Meta Relationship - Used By
| # | Relationship type | Used by | Short Description | Created on |
|---|---|---|---|---|
| 1 | Inheritance (c INHERITING FROM c_ref) | CL_RSDRC_SELC_FBDSO_SRVS | Service(s) for SELC - fbdso | 20130722 |
| 2 | Inheritance (c INHERITING FROM c_ref) | CL_RSDRC_SELC_IOBJ_SRVS | Service(s) for SELC | 20130722 |
Properties
| Class | CL_RSDRC_SELC_SRVS | |
| Short Description | Service(s) for SELC | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | RSDRC | Data Manager InfoProvider Read Access |
| Created | 20130718 | SAP |
| Last change | 20140121 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Forward declaration interface (INTERFACE i DEFINITION DEF... | Forward declaration interface (INTERFACE i DEFINITION DEF... | |
| 2 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 3 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 4 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 5 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) | |
| 6 | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_RSDRC_SELC_SRVS has no interface implemented.
Friends
Class CL_RSDRC_SELC_SRVS has no friend class.
Attributes
Class CL_RSDRC_SELC_SRVS has no attribute.
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Method for FBDSO dta - conversion to selc | 20130722 | |
| 2 | Instance method | Protected | Method | 20130718 | ||
| 3 | Instance method | Protected | Method | 20130718 | ||
| 4 | Instance method | Protected | Method | 20130718 | ||
| 5 | Static method | Protected | Method | 20130718 | ||
| 6 | Instance method | Protected | Method | 20130718 | ||
| 7 | Instance method | Protected | Method | 20130718 |
Events
Class CL_RSDRC_SELC_SRVS has no event.
Types
Class CL_RSDRC_SELC_SRVS has no local type.
Method Signatures
Method CONVERT_RANGES_TO_SELC Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_T_SELC | Call by reference | Type reference (TYPE) | RSDRC_T_SELC | 20130722 | ||||
| 2 | I_MOSTRECENT | Value transfer | Type reference (TYPE) | RS_BOOL | Boolean | 20130722 | |||
| 3 | I_TX_RANGETAB | Call by reference | Type reference (TYPE) | RSDRI_TX_RANGETAB | BW Data Manager: Table from Range List | 20130722 | |||
| 4 | I_T_RANGE | Call by reference | Type reference (TYPE) | RSDRI_T_RANGE | BW Data Manager: Range List | 20130722 |
Method CONVERT_RANGES_TO_SELC on class CL_RSDRC_SELC_SRVS has no exception.
Method _BUILD_SELC Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | C_INIT | Call by reference | Type reference (TYPE) | RS_BOOL | Boolean | 20130718 | |||
| 2 | C_T_SELC | Call by reference | Type reference (TYPE) | RSDRC_T_SELC | 20130718 | ||||
| 3 | I_FEMS | Call by reference | Type reference (TYPE) | RSDD_SX_SELDR-FEMS | BW: General reference field for internal IDs | 20130718 | |||
| 4 | I_MOSTRECENT | Call by reference | Type reference (TYPE) | RS_BOOL | Boolean | 20130718 | |||
| 5 | I_T_RANGE | Call by reference | Type reference (TYPE) | RSDRI_T_RANGE | BW Data Manager: Range List | 20130718 |
Method _BUILD_SELC on class CL_RSDRC_SELC_SRVS has no exception.
Method __ADD_ALWAYS_TRUE_CHAVL Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | C_T_RANGE | Call by reference | Type reference (TYPE) | RSDD_T_RANGE | Range expanded around SID | 20130718 | |||
| 2 | I_CHANM | Call by reference | Type reference (TYPE) | RSCHANM | Characteristic | 20130718 |
Method __ADD_ALWAYS_TRUE_CHAVL on class CL_RSDRC_SELC_SRVS has no exception.
Method __BUILD_TRUE_INCLUDING_SELC Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | C_INIT | Call by reference | Type reference (TYPE) | RS_BOOL | Boolean | 20130718 | |||
| 2 | C_T_SELC | Call by reference | Type reference (TYPE) | RSDRC_T_SELC | 20130718 | ||||
| 3 | I_CHANM | Call by reference | Type reference (TYPE) | RSCHANM | Characteristic | 20130718 | |||
| 4 | I_FEMS | Call by reference | Type reference (TYPE) | RSDD_SX_SELDR-FEMS | BW: General reference field for internal IDs | 20130718 |
Method __BUILD_TRUE_INCLUDING_SELC on class CL_RSDRC_SELC_SRVS has no exception.
Method __CONVERT_SEL_TO_SELC_SINGLE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | C_INIT | Call by reference | Type reference (TYPE) | RS_BOOL | Boolean | 20130718 | |||
| 2 | C_T_SELC | Call by reference | Type reference (TYPE) | RSDRC_T_SELC | 20130718 | ||||
| 3 | I_CHANM | Call by reference | Type reference (TYPE) | RSCHANM | Characteristic | 20130718 | |||
| 4 | I_FEMS | Call by reference | Type reference (TYPE) | RSDD_SX_SELDR-FEMS | BW: General reference field for internal IDs | 20130718 | |||
| 5 | I_FIELDNM | Call by reference | Type reference (TYPE) | RSD_FIELDNM | 20130718 | ||||
| 6 | I_MOSTRECENT | Call by reference | Type reference (TYPE) | RS_BOOL | Boolean | 20130718 | |||
| 7 | I_REDUNDANT | Call by reference | Type reference (TYPE) | RS_BOOL | Boolean | 20130718 | |||
| 8 | I_SELT_TABIX | Call by reference | Type reference (TYPE) | I | 20130718 | ||||
| 9 | I_S_RANGE | Call by reference | Type reference (TYPE) | RSDD_S_RANGE | 20130718 | ||||
| 10 | I_TABNM | Call by reference | Type reference (TYPE) | RSD_TABLNM | 20130718 | ||||
| 11 | I_TH_CHAVL | Call by reference | Type reference (TYPE) | RSDRS_TH_CHAVL | 20130718 | ||||
| 12 | I_TH_EQSID | Call by reference | Type reference (TYPE) | RSDD_SX_SELDR-EQSID | 20130718 |
Method __CONVERT_SEL_TO_SELC_SINGLE on class CL_RSDRC_SELC_SRVS has no exception.
Method __GET_COB_PRO_ENTRY Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_S_COB_PRO | Call by reference | Type reference (TYPE) | RSD_S_COB_PRO | InfoObject Properties (in Context of InfoCube / ODS Object) | 20130718 | |||
| 2 | I_OBJNM | Call by reference | Type reference (TYPE) | CHAR30 | here field or iobjnm is both ok | 20130722 |
Method __GET_COB_PRO_ENTRY on class CL_RSDRC_SELC_SRVS has no exception.
Method __GET_INITIAL_VALUE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_CHAVL | Call by reference | Type reference (TYPE) | RSCHAVL | Dim: Field for a User-Defined Characteristic Value | 20130718 | |||
| 2 | E_NUMFL | Call by reference | Type reference (TYPE) | RS_BOOL | Boolean | 20130718 | |||
| 3 | I_DIGITS | Call by reference | Type reference (TYPE) | RSDIGITS | Number of Characters in Field | 20130718 | |||
| 4 | I_INTTP | Call by reference | Type reference (TYPE) | C | 20130718 |
Method __GET_INITIAL_VALUE on class CL_RSDRC_SELC_SRVS has no exception.
History
| Last changed by/on | SAP | 20140121 |
| SAP Release Created in | 740 |