SAP ABAP Class CL_RSDME_UI_WHAT_IF_INPUT_GRID (Grid for setting Input field values)
Hierarchy
☛
SAP_BW (Software Component) SAP Business Warehouse
⤷
BW-EI-DM (Application Component) Data Mining
⤷
RS_DME_UI_OO (Package) Datamining UI related - OO Based

⤷

⤷

Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_RSDME_WI_UI_SCREEN | Prediction Screens | 20030908 |
Meta Relationship - Used By
# | Relationship type | Used by | Short Description | Created on |
---|---|---|---|---|
1 | Inheritance (c INHERITING FROM c_ref) | CL_RSDME_UI_WHAT_IF_IP_GRID_DT | Grid for setting Input field values - DTree | 20040123 |
Properties
Class | CL_RSDME_UI_WHAT_IF_INPUT_GRID | |
Short Description | Grid for setting Input field values | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | RS_DME_UI_OO | Datamining UI related - OO Based |
Created | 20030908 | SAP |
Last change | 20110908 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
2 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_RSDME_WI_UI_SCREEN | Prediction Screens | 20030908 |
Friends
Class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
Constant | Protected | Type reference (TYPE) | CHAR10 | 'CC_INPUT' | 20030908 | ||
2 | ![]() |
Constant | Protected | Type reference (TYPE) | SY-DYNNR | '0200' | 20030908 | ||
3 | ![]() |
Constant | Protected | Type reference (TYPE) | SY-REPID | 'SAPLRS_DME_UI_WHATIF_OO' | 20030908 | ||
4 | ![]() |
Constant | Protected | Type reference (TYPE) | STRUKNAME | 'RSDMSI_PRED_WHATIF_INPUT' | Structure Name | 20030908 | |
5 | ![]() |
Instance attribute | Protected | Object reference (TYPE REF TO) | IF_RSDME_WHATIF_UI_CTRL | 20030908 | |||
6 | ![]() |
Instance attribute | Protected | Object reference (TYPE REF TO) | CL_GUI_CUSTOM_CONTAINER | 20030908 | |||
7 | ![]() |
Instance attribute | Protected | Object reference (TYPE REF TO) | CL_GUI_ALV_GRID | 20030908 | |||
8 | ![]() |
Instance attribute | Protected | Type reference (TYPE) | RSDMSI_T_PRED_WHATIF_INPUT | 20030908 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Protected | Method | Check Individual Selection | 20030908 |
2 | ![]() |
Instance method | Private | Method | Create field catalog | 20030908 |
3 | ![]() |
Instance method | Private | Method | Create Field F4 | 20030908 |
4 | ![]() |
Instance method | Private | Method | Create Grid Object | 20030908 |
5 | ![]() |
Instance method | Private | Method | Create Grid Layout | 20030908 |
6 | ![]() |
Instance method | Protected | Method | Launch Dialog for F4 | 20030908 |
7 | ![]() |
Instance method | Private | Method | Get Field List with Description | 20030908 |
8 | ![]() |
Instance method | Protected | Method | Get F4 Values from Model | 20030908 |
9 | ![]() |
Instance method | Private | Event handling method | Handle Data Changed Event | 20030908 |
10 | ![]() |
Instance method | Private | Event handling method | Handle F4 event for Value Help | 20030908 |
Events
Class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no event.
Types
Class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no local type.
Method Signatures
Method CHECK_SELECTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IR_DATA_CHANGED | Call by reference | Object reference (TYPE REF TO) | CL_ALV_CHANGED_DATA_PROTOCOL | 20030908 | |||
2 | ![]() |
IS_GOOD | Call by reference | Type reference (TYPE) | LVC_S_MODI | 20030908 |
Method CHECK_SELECTION on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no exception.
Method CREATE_FIELD_CATALOG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RT_FCAT | Value transfer | Type reference (TYPE) | LVC_T_FCAT | 20030908 |
Method CREATE_FIELD_CATALOG on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no exception.
Method CREATE_FIELD_F4 Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RT_F4 | Value transfer | Type reference (TYPE) | LVC_T_F4 | 20030908 |
Method CREATE_FIELD_F4 on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no exception.
Method CREATE_GRID Signature
Method CREATE_GRID on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no parameter.
Method CREATE_GRID on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no exception.
Method CREATE_LAYOUT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RS_LAYOUT | Value transfer | Type reference (TYPE) | LVC_S_LAYO | 20030908 |
Method CREATE_LAYOUT on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no exception.
Method DISPLAY_F4 Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_SELECTED | Value transfer | Type reference (TYPE) | STRING | 20030908 | |||
2 | ![]() |
I_T_VALUES_F4 | Call by reference | Type reference (TYPE) | RSDMU_T_GEN_VAL_F4 | 20030908 |
Method DISPLAY_F4 on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no exception.
Method GET_DATA Signature
Method GET_DATA on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no parameter.
Method GET_DATA on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no exception.
Method GET_F4_VALUES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
E_T_VALUES_F4 | Value transfer | Type reference (TYPE) | RSDMU_T_GEN_VAL_F4 | 20030908 | |||
2 | ![]() |
I_FIELD | Call by reference | Type reference (TYPE) | RSDMEM_COLUMN_NAME | 20030908 |
Method GET_F4_VALUES on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no exception.
Method HANDLE_DATA_CHANGED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ER_DATA_CHANGED | Call by reference | Attribute reference (LIKE) | 20030908 | ||||
2 | ![]() |
E_ONF4 | Call by reference | Attribute reference (LIKE) | 20030908 | ||||
3 | ![]() |
E_ONF4_AFTER | Call by reference | Attribute reference (LIKE) | 20030908 | ||||
4 | ![]() |
E_ONF4_BEFORE | Call by reference | Attribute reference (LIKE) | 20030908 | ||||
5 | ![]() |
E_UCOMM | Call by reference | Attribute reference (LIKE) | 20030908 | ||||
6 | ![]() |
SENDER | Call by reference | Attribute reference (LIKE) | 20030908 |
Method HANDLE_DATA_CHANGED on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no exception.
Method HANDLE_F4 Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
ER_EVENT_DATA | Call by reference | Attribute reference (LIKE) | 20030908 | ||||
2 | ![]() |
ES_ROW_NO | Call by reference | Attribute reference (LIKE) | 20030908 | ||||
3 | ![]() |
ET_BAD_CELLS | Call by reference | Attribute reference (LIKE) | 20030908 | ||||
4 | ![]() |
E_DISPLAY | Call by reference | Attribute reference (LIKE) | 20030908 | ||||
5 | ![]() |
E_FIELDNAME | Call by reference | Attribute reference (LIKE) | 20030908 | ||||
6 | ![]() |
E_FIELDVALUE | Call by reference | Attribute reference (LIKE) | 20030908 |
Method HANDLE_F4 on class CL_RSDME_UI_WHAT_IF_INPUT_GRID has no exception.
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in | 350 |