SAP ABAP Class CL_FPM_HCT_WIRE_MODEL_VAL (FPM Configuration: Wire Model Controller)
Hierarchy
SAP_UI (Software Component) User Interface Technology
   BC-WD-CMP-FPM (Application Component) Floorplan Manager Web Dynpro ABAP
     APB_FPM_HCT (Package) Harmonized Configuration Tool
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Inheritance (c INHERITING FROM c_ref)  CL_FPM_HCT_VALIDATION Validation of Configuration 20090603
Properties
Class CL_FPM_HCT_WIRE_MODEL_VAL  
Short Description FPM Configuration: Wire Model Controller    
Super Class CL_FPM_HCT_VALIDATION Validation of Configuration 
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package APB_FPM_HCT   Harmonized Configuration Tool 
Created 20090603   SAP 
Last change 20130531   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 ABAP Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 CL_FPM_HCT_WIRE_MODEL_ASSIST Forward declaration class (CLASS c DEFINITION DEFERRED)  Forward declaration class (CLASS c DEFINITION DEFERRED)
Interfaces
Class CL_FPM_HCT_WIRE_MODEL_VAL has no interface implemented.
Friends
Class CL_FPM_HCT_WIRE_MODEL_VAL has no friend class.
Attributes
# Attribute Level Visibility Read only Typing Associated Type Initial Value Description Created on
1 MT_MODEL Instance attribute Private Type reference (TYPE) CL_FPM_HCT_WIRE_MODEL_ASSIST=>TY_T_UIBB_INSTANCE_KEY 20090603
Methods
# Method Level Visibility Method type Description Created on
1 CHECK_CONNECTOR Instance method Protected Method Checks the connector class 20091023
2 CHECK_ELEMENT Instance method Protected Method Check single element 20090603
3 CHECK_MODEL Instance method Protected Method Check model validity (source/target) 20090603
4 CHECK_TARGET_UNIQUENESS Instance method Protected Method Checks whether wire targets are unique 20090603
5 CHECK_TRANSIENT_STATE Instance method Protected Method 20120814
6 GET_ASSIST Instance method Protected Method 20101011
Events
Class CL_FPM_HCT_WIRE_MODEL_VAL has no event.
Types
Class CL_FPM_HCT_WIRE_MODEL_VAL has no local type.
Method Signatures

Method CHECK_CONNECTOR Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_VIEW_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Interface for Node Element 20091023
2 Importing IV_CONNECTOR Call by reference Type reference (TYPE) FPM_WIRE_MODEL_CONNECTOR FPM Wire Model: Connector Class 20091023
3 Importing IV_SOURCE_NAMESPACE Call by reference Type reference (TYPE) FPM_MODEL_NAMESPACE FPM Wire Model: Namespace 20091023
4 Importing IV_TARGET_NAMESPACE Call by reference Type reference (TYPE) FPM_MODEL_NAMESPACE FPM Wire Model: Namespace 20091023
5 Returning RV_SUCCESS Value transfer Type reference (TYPE) ABAP_BOOL Successful 20091023

Method CHECK_CONNECTOR on class CL_FPM_HCT_WIRE_MODEL_VAL has no exception.

Method CHECK_ELEMENT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IO_SELECTED_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Interface for Node Element 20090603
2 Importing IO_VIEW_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Interface for Node Element 20090603
3 Importing IV_GLOBAL_CHECK Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE 20090603
4 Returning RV_SUCCESS Value transfer Type reference (TYPE) ABAP_BOOL 20090603

Method CHECK_ELEMENT on class CL_FPM_HCT_WIRE_MODEL_VAL has no exception.

Method CHECK_MODEL Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CV_SUCCESS Call by reference Type reference (TYPE) ABAP_BOOL 20090603
2 Exporting EV_IS_VALID Call by reference Type reference (TYPE) ABAP_BOOL 20090603
3 Importing IO_SELECTED_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Interface for Node Element 20090603
4 Importing IO_VIEW_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Interface for Node Element 20090603
5 Importing IV_GLOBAL_CHECK Call by reference Type reference (TYPE) ABAP_BOOL 20090603
6 Importing IV_SOURCE_INDICATOR Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE 20090603
7 Importing IV_WIRE_PLUG Call by reference Type reference (TYPE) ABAP_BOOL ABAP_FALSE 20091023

Method CHECK_MODEL on class CL_FPM_HCT_WIRE_MODEL_VAL has no exception.

Method CHECK_TARGET_UNIQUENESS Signature

Method CHECK_TARGET_UNIQUENESS on class CL_FPM_HCT_WIRE_MODEL_VAL has no parameter.
Method CHECK_TARGET_UNIQUENESS on class CL_FPM_HCT_WIRE_MODEL_VAL has no exception.

Method CHECK_TRANSIENT_STATE Signature

Method CHECK_TRANSIENT_STATE on class CL_FPM_HCT_WIRE_MODEL_VAL has no parameter.
Method CHECK_TRANSIENT_STATE on class CL_FPM_HCT_WIRE_MODEL_VAL has no exception.

Method GET_ASSIST Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RO_ASSIST Value transfer Object reference (TYPE REF TO) CL_FPM_HCT_WIRE_MODEL_ASSIST Assistance class for wire model configuration 20101011

Method GET_ASSIST on class CL_FPM_HCT_WIRE_MODEL_VAL has no exception.
History
Last changed by/on SAP  20130531 
SAP Release Created in 730