SAP ABAP Class CL_FPM_BICS_WIRE_ENTITY (BICS object for wiring)
Hierarchy
☛
SAP_BW (Software Component) SAP Business Warehouse
⤷
BW-RUI-FPM (Application Component) FPM Analytical GUIBB
⤷
BW_REPORTING_FPM (Package) FPM UIBBs

⤷

⤷

Properties
Class | CL_FPM_BICS_WIRE_ENTITY | |
Short Description | BICS object for wiring | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | BW_REPORTING_FPM | FPM UIBBs |
Created | 20130709 | SAP |
Last change | 20140121 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class CL_FPM_BICS_WIRE_ENTITY has no forward declaration.
Interfaces
Class CL_FPM_BICS_WIRE_ENTITY has no interface implemented.
Friends
Class CL_FPM_BICS_WIRE_ENTITY has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
Instance attribute | Private | Object reference (TYPE REF TO) | IF_BICS_QV | 20130709 | |||
2 | ![]() |
Instance attribute | Private | Object reference (TYPE REF TO) | IF_FPM_BICS_SELECTION | FPM internal BICS selection collection | 20130715 | ||
3 | ![]() |
Instance attribute | Private | Object reference (TYPE REF TO) | IF_FPM_BICS_SELECTION | FPM internal BICS selection collection | 20130715 | ||
4 | ![]() |
Instance attribute | Private | Type reference (TYPE) | FPM_BICS_INSTANCE_ID | BICS Instance ID | 20130716 | ||
5 | ![]() |
Instance attribute | Private | Type reference (TYPE) | CL_FPM_BICS_FEEDER=>TY_OUTPORT_SUBTYPE | 20130715 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | ![]() |
Instance method | Public | Constructor | 20130709 | |
2 | ![]() |
Instance method | Public | Method | 20130716 | |
3 | ![]() |
Instance method | Public | Method | 20130715 | |
4 | ![]() |
Instance method | Public | Method | 20130709 | |
5 | ![]() |
Instance method | Public | Method | 20130709 | |
6 | ![]() |
Instance method | Public | Method | 20130709 | |
7 | ![]() |
Instance method | Public | Method | 20130716 | |
8 | ![]() |
Instance method | Public | Method | 20130715 | |
9 | ![]() |
Instance method | Public | Method | 20130709 | |
10 | ![]() |
Instance method | Public | Method | 20130709 | |
11 | ![]() |
Instance method | Public | Method | 20130709 |
Events
Class CL_FPM_BICS_WIRE_ENTITY has no event.
Types
Class CL_FPM_BICS_WIRE_ENTITY has no local type.
Method Signatures
Method CONSTRUCTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_QUERY | Call by reference | Object reference (TYPE REF TO) | IF_BICS_QV | 20130709 | |||
2 | ![]() |
IO_SEARCH_CRITERIA | Call by reference | Object reference (TYPE REF TO) | IF_FPM_BICS_SELECTION | 20130715 | |||
3 | ![]() |
IO_SELECTION | Call by reference | Object reference (TYPE REF TO) | IF_FPM_BICS_SELECTION | 20130715 | |||
4 | ![]() |
IV_INSTANCE_ID | Call by reference | Type reference (TYPE) | FPM_BICS_INSTANCE_ID | BICS Instance ID | 20130716 | ||
5 | ![]() |
IV_TYPE | Call by reference | Type reference (TYPE) | CL_FPM_BICS_FEEDER=>TY_OUTPORT_SUBTYPE | 20130715 |
Method CONSTRUCTOR on class CL_FPM_BICS_WIRE_ENTITY has no exception.
Method GET_INSTANCE_ID Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RV_INSTANCE_ID | Value transfer | Type reference (TYPE) | FPM_BICS_INSTANCE_ID | 20130716 |
Method GET_INSTANCE_ID on class CL_FPM_BICS_WIRE_ENTITY has no exception.
Method GET_OUTPORT_SUBTYPE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RV_TYPE | Value transfer | Type reference (TYPE) | CL_FPM_BICS_FEEDER=>TY_OUTPORT_SUBTYPE | 20130715 |
Method GET_OUTPORT_SUBTYPE on class CL_FPM_BICS_WIRE_ENTITY has no exception.
Method GET_QUERY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RO_QUERY | Value transfer | Object reference (TYPE REF TO) | IF_BICS_QV | 20130709 |
Method GET_QUERY on class CL_FPM_BICS_WIRE_ENTITY has no exception.
Method GET_SEARCH_CRITERIA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RO_SEARCH_CRITERIA | Value transfer | Object reference (TYPE REF TO) | IF_FPM_BICS_SELECTION | 20130715 |
Method GET_SEARCH_CRITERIA on class CL_FPM_BICS_WIRE_ENTITY has no exception.
Method GET_SELECTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RO_SELECTION | Value transfer | Object reference (TYPE REF TO) | IF_FPM_BICS_SELECTION | 20130715 |
Method GET_SELECTION on class CL_FPM_BICS_WIRE_ENTITY has no exception.
Method SET_INSTANCE_ID Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_INSTANCE_ID | Call by reference | Type reference (TYPE) | FPM_BICS_INSTANCE_ID | 20130716 |
Method SET_INSTANCE_ID on class CL_FPM_BICS_WIRE_ENTITY has no exception.
Method SET_OUTPORT_SUBTYPE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_TYPE | Call by reference | Type reference (TYPE) | CL_FPM_BICS_FEEDER=>TY_OUTPORT_SUBTYPE | 20130715 |
Method SET_OUTPORT_SUBTYPE on class CL_FPM_BICS_WIRE_ENTITY has no exception.
Method SET_QUERY Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_QUERY | Call by reference | Object reference (TYPE REF TO) | IF_BICS_QV | 20130709 |
Method SET_QUERY on class CL_FPM_BICS_WIRE_ENTITY has no exception.
Method SET_SEARCH_CRITERIA Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_SEARCH_CRITERIA | Call by reference | Object reference (TYPE REF TO) | IF_FPM_BICS_SELECTION | 20130715 |
Method SET_SEARCH_CRITERIA on class CL_FPM_BICS_WIRE_ENTITY has no exception.
Method SET_SELECTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IO_SELECTION | Call by reference | Object reference (TYPE REF TO) | IF_FPM_BICS_SELECTION | 20130715 |
Method SET_SELECTION on class CL_FPM_BICS_WIRE_ENTITY has no exception.
History
Last changed by/on | SAP | 20140121 |
SAP Release Created in | 740 |