SAP ABAP Class CL_FPM_ATTR_FILT_CONFIG_READER (Configuration Reader for Attribute Filter GUIBB)
Hierarchy
☛
SAP_UI (Software Component) User Interface Technology
⤷ BC-WD-CMP-FPM (Application Component) Floorplan Manager Web Dynpro ABAP
⤷ APB_FPM_GUIBB (Package) Generic UI building blocks
⤷ BC-WD-CMP-FPM (Application Component) Floorplan Manager Web Dynpro ABAP
⤷ APB_FPM_GUIBB (Package) Generic UI building blocks
Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Inheritance (c INHERITING FROM c_ref) | CL_FPM_CONFIG_READER | Configuration Reader for OIF | 20140519 |
Properties
Class | CL_FPM_ATTR_FILT_CONFIG_READER | |
Short Description | Configuration Reader for Attribute Filter GUIBB | |
Super Class | CL_FPM_CONFIG_READER | Configuration Reader for OIF |
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | APB_FPM_GUIBB | Generic UI building blocks |
Created | 20140519 | SAP |
Last change | 20141120 | |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | IF_FPM_GUIBB_ATTR_FILTER_TYPES | Forward declaration interface (INTERFACE i DEFINITION DEF... | Forward declaration interface (INTERFACE i DEFINITION DEF... |
Interfaces
Class CL_FPM_ATTR_FILT_CONFIG_READER has no interface implemented.
Friends
Class CL_FPM_ATTR_FILT_CONFIG_READER has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | MS_CONFIG | Instance attribute | Private | Type reference (TYPE) | IF_FPM_GUIBB_ATTR_FILTER_TYPES=>TS_CONFIG | 20140519 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | CONSTRUCTOR | Instance method | Public | Constructor | CONSTRUCTOR | 20140519 |
2 | GET_ATTRIBUTES | Instance method | Public | Method | 20140519 | |
3 | GET_FEEDER | Instance method | Public | Method | 20140519 | |
4 | GET_PARAMETERS | Instance method | Public | Method | 20140519 | |
5 | GET_SETTINGS | Instance method | Public | Method | 20140519 |
Events
Class CL_FPM_ATTR_FILT_CONFIG_READER has no event.
Types
# | Type | Visibility | Typing | Associated Type | Description | Created on | Type Source |
---|---|---|---|---|---|---|---|
1 | TT_ATTRIBUTE | Public | Type reference (TYPE) | IF_FPM_GUIBB_ATTR_FILTER_TYPES=>TT_ATTRIBUTE_DATA | 20140519 | |
Method Signatures
Method CONSTRUCTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IR_APPL_READER | Call by reference | Object reference (TYPE REF TO) | IF_WD_CONFIG_APPL_READER | Read Interface for Application Configuration | 20140519 | ||
2 | Importing | IR_COMP_READER | Call by reference | Object reference (TYPE REF TO) | IF_WD_CONFIG_COMP_READER | Read Interface for the Component Configuration | 20140519 | ||
3 | Importing | IV_CONFIGURATION_ID | Call by reference | Type reference (TYPE) | WDY_CONFIG_ID | Configuration Identification | 20140519 | ||
4 | Importing | IV_CONFIG_TYPE | Call by reference | Type reference (TYPE) | WDY_CONFIG_TYPE | Type of Web Dynpro Configuration | 20140519 | ||
5 | Importing | IV_NO_VARIANTS | Call by reference | Type reference (TYPE) | BOOLE_D | ABAP_FALSE | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20140519 |
# | Exception | Resumable | Description | Created on |
---|---|---|---|---|
1 | CX_FPM_FLOORPLAN | Floorplan exceptions | 20140519 |
Method GET_ATTRIBUTES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RT_ATTRIBUTE | Value transfer | Type reference (TYPE) | TT_ATTRIBUTE | 20140519 |
Method GET_ATTRIBUTES on class CL_FPM_ATTR_FILT_CONFIG_READER has no exception.
Method GET_FEEDER Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RV_FEEDER | Value transfer | Type reference (TYPE) | FPMGB_FEEDER_CLASS | Feeder Class | 20140519 |
Method GET_FEEDER on class CL_FPM_ATTR_FILT_CONFIG_READER has no exception.
Method GET_PARAMETERS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RT_PARAMETER | Value transfer | Type reference (TYPE) | IF_FPM_GUIBB_ATTR_FILTER_TYPES=>TT_PARAMETER | 20140519 |
Method GET_PARAMETERS on class CL_FPM_ATTR_FILT_CONFIG_READER has no exception.
Method GET_SETTINGS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Returning | RS_SETTINGS | Value transfer | Type reference (TYPE) | IF_FPM_GUIBB_ATTR_FILTER_TYPES=>TS_SETTINGS | 20140519 |
Method GET_SETTINGS on class CL_FPM_ATTR_FILT_CONFIG_READER has no exception.
History
Last changed by/on | SAP | 20141120 |
SAP Release Created in | 740 |