SAP ABAP Class CL_CMS_RE_VAL_FOBU (Valuation Formula builder connector)
Hierarchy
☛
EA-FINSERV (Software Component) SAP Enterprise Extension Financial Services
⤷ FS-CMS-MD-RE (Application Component) Real Estate
⤷ CMS_RE (Package) Collateral Management System: Real Esate
⤷ FS-CMS-MD-RE (Application Component) Real Estate
⤷ CMS_RE (Package) Collateral Management System: Real Esate
Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_FOBU_APPL_CALLBACK | Formula Builder: Application Callback | 20021111 |
2 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_FOBU_CONNECTOR | Formula Builder: Interface Addapter for Formula Builder | 20021111 |
3 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_FOEV_CONNECTOR | FoBuEv: Interface Adapter for Evaluation | 20021121 |
Properties
Class | CL_CMS_RE_VAL_FOBU | |
Short Description | Valuation Formula builder connector | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | CMS_RE | Collateral Management System: Real Esate |
Created | 20021111 | SAP |
Last change | 00000000 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
Class CL_CMS_RE_VAL_FOBU has no forward declaration.
Interfaces
# | Interface | Abstract | Final | Description | Created on |
---|---|---|---|---|---|
1 | IF_FOBU_APPL_CALLBACK | Formula Builder: Application Callback | 20021111 | ||
2 | IF_FOBU_CONNECTOR | Formula Builder: Interface Addapter for Formula Builder | 20021111 | ||
3 | IF_FOEV_CONNECTOR | FoBuEv: Interface Adapter for Evaluation | 20021121 |
Friends
Class CL_CMS_RE_VAL_FOBU has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | CON_MSG_CLASS | Constant | Private | Type reference (TYPE) | SY-MSGID | 'CMS_RE_VAL' | Messages, Message Class | 20021209 | |
2 | CON_MSG_ERROR | Constant | Private | Type reference (TYPE) | SY-MSGTY | 'E' | Return Code from a Method or Function Module | 20021209 | |
3 | CON_RC_DEF_ERROR | Constant | Private | Type reference (TYPE) | CMS_DTE_RETURN_CODE | 3005 | Return Code from a Method or Function Module | 20021209 | |
4 | CON_RC_EVAL_ERROR | Constant | Private | Type reference (TYPE) | CMS_DTE_RETURN_CODE | 3004 | Return Code from a Method or Function Module | 20021209 | |
5 | G_STR_OBJ_PRT | Static Attribute | Private | Type reference (TYPE) | CMS_RE_STR_OBJ_PRT | Structure for Object Part(without mandt) | 20030106 | ||
6 | G_STR_PRT_ACS | Static Attribute | Private | Type reference (TYPE) | CMS_RE_STR_PRT_ACS | Structure for Object Accessories (without mandt) | 20021125 | ||
7 | G_STR_PRT_CST | Static Attribute | Private | Type reference (TYPE) | CMS_RE_STR_PRT_CST | Structure for Part Cost (without mandt) | 20021125 | ||
8 | G_STR_RE_VAL_PARAM | Static Attribute | Private | Type reference (TYPE) | CMS_STR_RE_VAL_PARAM | Valuation parameters structure | 20021125 |
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | CONSTRUCTOR | Instance method | Public | Constructor | CONSTRUCTOR | 20021125 |
2 | SET_MSG_COL | Static method | Private | Method | Assign message according to Message number | 20021209 |
3 | SIGMA_ACS | Static method | Public | Method | Evaluation of a table of building parts and accessories | 20021203 |
4 | SIGMA_CST | Static method | Public | Method | Evaluation of a table of building parts and costs | 20021126 |
5 | SIGMA_PRT | Static method | Public | Method | Evaluation of a formula on every row of building parts table | 20021206 |
Events
Class CL_CMS_RE_VAL_FOBU has no event.
Types
Class CL_CMS_RE_VAL_FOBU has no local type.
Method Signatures
Method CONSTRUCTOR Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_STR_RE_VAL_PARAM | Value transfer | Type reference (TYPE) | CMS_STR_RE_VAL_PARAM | Bewertungsparameterstruktur | 20021125 |
Method CONSTRUCTOR on class CL_CMS_RE_VAL_FOBU has no exception.
Method SET_MSG_COL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | IM_STR_MSG_COL_MESG | Call by reference | Type reference (TYPE) | CMS_STR_MSG_COL_MESSAGE | Format für Rückgabewert und entsprechende Nachricht | 20021209 |
Method SET_MSG_COL on class CL_CMS_RE_VAL_FOBU has no exception.
Method SIGMA_ACS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EX_COMP_VAL | Call by reference | Type reference (TYPE) | F | 20021203 | |||
2 | Importing | IM_COMP_ID | Call by reference | Type reference (TYPE) | CMS_DTE_VAL_COMP_ID | Name der Komponente für Teile & Zubehör - ohne Anf.zeichen | 20021203 |
Method SIGMA_ACS on class CL_CMS_RE_VAL_FOBU has no exception.
Method SIGMA_CST Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EX_COMP_VAL | Call by reference | Type reference (TYPE) | F | 20021126 | |||
2 | Importing | IM_COMP_ID | Call by reference | Type reference (TYPE) | CMS_DTE_VAL_COMP_ID | Name der Komponente für Teile & Kosten - ohne Anf.zeichen | 20021126 |
Method SIGMA_CST on class CL_CMS_RE_VAL_FOBU has no exception.
Method SIGMA_PRT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Exporting | EX_COMP_VAL | Call by reference | Type reference (TYPE) | F | 20021206 | |||
2 | Importing | IM_COMP_ID | Call by reference | Type reference (TYPE) | CMS_DTE_VAL_COMP_ID | Name der Komponente für Immo.gebäudeteile - ohne Anf.zeichen | 20021206 |
Method SIGMA_PRT on class CL_CMS_RE_VAL_FOBU has no exception.
History
Last changed by/on | SAP | 00000000 |
SAP Release Created in | 200 |