SAP ABAP Class CL_CHIP_EXEC_HELPER (CHIP Static Execution Helper)
Hierarchy
☛
SAP_UI (Software Component) User Interface Technology
⤷ BC-WD-ABA-PB (Application Component) WD ABAP Page Builder
⤷ SWDP_CCP_API (Package) Web Dynpro ABAP: CCP Integration API
⤷ BC-WD-ABA-PB (Application Component) WD ABAP Page Builder
⤷ SWDP_CCP_API (Package) Web Dynpro ABAP: CCP Integration API
Properties
Class | CL_CHIP_EXEC_HELPER | |
Short Description | CHIP Static Execution Helper | |
Super Class | ||
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | SWDP_CCP_API | Web Dynpro ABAP: CCP Integration API |
Created | 20100304 | SAP |
Last change | 20110908 | SAP |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ABAP | Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class CL_CHIP_EXEC_HELPER has no interface implemented.
Friends
Class CL_CHIP_EXEC_HELPER has no friend class.
Attributes
Class CL_CHIP_EXEC_HELPER has no attribute.
Methods
# | Method | Level | Visibility | Method type | Description | Created on |
---|---|---|---|---|---|---|
1 | CHECK_LOCAL_INSTANCE_EXECUTION | Static method | Public | Method | 20100304 | |
2 | CHECK_REMOTE | Static method | Private | Method | 20100310 | |
3 | CHECK_REMOTE_APPL | Static method | Private | Method | 20100310 | |
4 | CHECK_REMOTE_EXECUTION | Static method | Public | Method | 20100304 | |
5 | GET_EXECUTE_FULLSCREEN | Static method | Public | Method | 20110421 | |
6 | GET_EXECUTE_REMOTE | Static method | Public | Method | 20100609 | |
7 | GET_EXECUTE_STATIC | Static method | Public | Method | 20100609 | |
8 | GET_LAUNCHER_APP | Static method | Public | Method | 20100609 | |
9 | GET_LAUNCHER_APP_CONFIG | Static method | Public | Method | 20100609 | |
10 | GET_MESSAGE_IS_NOT_REMOTE | Static method | Public | Method | 20100609 |
Events
Class CL_CHIP_EXEC_HELPER has no event.
Types
Class CL_CHIP_EXEC_HELPER has no local type.
Method Signatures
Method CHECK_LOCAL_INSTANCE_EXECUTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CHIP_DEFINITION | Call by reference | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100304 | ||
2 | Returning | RESULT | Value transfer | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100304 |
Method CHECK_LOCAL_INSTANCE_EXECUTION on class CL_CHIP_EXEC_HELPER has no exception.
Method CHECK_REMOTE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CHIP_DEFINITION | Call by reference | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100310 | ||
2 | Returning | RESULT | Value transfer | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100310 |
Method CHECK_REMOTE on class CL_CHIP_EXEC_HELPER has no exception.
Method CHECK_REMOTE_APPL Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CHIP_DEFINITION | Call by reference | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100310 | ||
2 | Returning | RESULT | Value transfer | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100310 | ||
3 | Importing | WD_COMPONENT | Call by reference | Object reference (TYPE REF TO) | IF_WD_COMPONENT | Web Dynpro: Component | 20100310 |
Method CHECK_REMOTE_APPL on class CL_CHIP_EXEC_HELPER has no exception.
Method CHECK_REMOTE_EXECUTION Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CHIP_DEFINITION | Call by reference | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100304 | ||
2 | Returning | RESULT | Value transfer | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100304 | ||
3 | Importing | WD_COMPONENT | Call by reference | Object reference (TYPE REF TO) | IF_WD_COMPONENT | Web Dynpro: Component | 20100310 |
Method CHECK_REMOTE_EXECUTION on class CL_CHIP_EXEC_HELPER has no exception.
Method GET_EXECUTE_FULLSCREEN Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CHIP_DEFINITION | Call by reference | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20110421 | ||
2 | Returning | EXECUTE_FULLSCREEN | Value transfer | Type reference (TYPE) | ABAP_BOOL | 20110421 |
Method GET_EXECUTE_FULLSCREEN on class CL_CHIP_EXEC_HELPER has no exception.
Method GET_EXECUTE_REMOTE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CHIP_DEFINITION | Call by reference | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100609 | ||
2 | Returning | EXECUTE_REMOTE | Value transfer | Type reference (TYPE) | ABAP_BOOL | 20100609 |
Method GET_EXECUTE_REMOTE on class CL_CHIP_EXEC_HELPER has no exception.
Method GET_EXECUTE_STATIC Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CHIP_DEFINITION | Call by reference | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100609 | ||
2 | Returning | EXECUTE_STATIC | Value transfer | Type reference (TYPE) | ABAP_BOOL | 20100609 |
Method GET_EXECUTE_STATIC on class CL_CHIP_EXEC_HELPER has no exception.
Method GET_LAUNCHER_APP Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CHIP_DEFINITION | Call by reference | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100609 | ||
2 | Returning | LAUNCHER_APP | Value transfer | Type reference (TYPE) | STRING | 20100609 |
Method GET_LAUNCHER_APP on class CL_CHIP_EXEC_HELPER has no exception.
Method GET_LAUNCHER_APP_CONFIG Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CHIP_DEFINITION | Call by reference | Object reference (TYPE REF TO) | IF_CHIP_DEFINITION | CHIP Definition | 20100609 | ||
2 | Returning | LAUNCHER_APP_CONFIG | Value transfer | Type reference (TYPE) | STRING | 20100609 |
Method GET_LAUNCHER_APP_CONFIG on class CL_CHIP_EXEC_HELPER has no exception.
Method GET_MESSAGE_IS_NOT_REMOTE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | Importing | CHIP_NAME | Call by reference | Type reference (TYPE) | STRING | 20100609 | |||
2 | Returning | MESSAGE | Value transfer | Type reference (TYPE) | STRING | 20100609 |
Method GET_MESSAGE_IS_NOT_REMOTE on class CL_CHIP_EXEC_HELPER has no exception.
History
Last changed by/on | SAP | 20110908 |
SAP Release Created in | 703 |