SAP ABAP Class /RPM/CL_DOC_COLL_PROXY_EDMS (Proxy for Administration of CFX Objekts in cProjects)
Hierarchy
☛
CPRXRPM (Software Component) SAP Portfolio and Project Management 6.0
⤷
PPM-PFM (Application Component) Portfolio Management
⤷
/RPM/DOCUMENT (Package) RPM Document Objects

⤷

⤷

Meta Relationship - Using
# | Relationship type | Using | Short Description | Created on |
---|---|---|---|---|
1 | Inheritance (c INHERITING FROM c_ref) | /RPM/CL_DOC_COLL_PROXY | Proxy for Administration of CFX/EDMS Objects | 20080604 |
Properties
Class | /RPM/CL_DOC_COLL_PROXY_EDMS | |
Short Description | Proxy for Administration of CFX Objekts in cProjects | |
Super Class | /RPM/CL_DOC_COLL_PROXY | Proxy for Administration of CFX/EDMS Objects |
Instantiability of a Class | 2 | Public |
Final |
General Data
Message Class | ||
Program status | ||
Category | 0 | |
Package | /RPM/DOCUMENT | RPM Document Objects |
Created | 20080604 | SAP |
Last change | 20141109 | |
Shared Memory-enabled | ||
Fixed point arithmetic | ||
Unicode checks active |
Forward declarations
# | Type group / Object type | Type | Type Description |
---|---|---|---|
1 | ![]() |
Type group use (TYPE-POOLS tp) | Type group use (TYPE-POOLS tp) |
Interfaces
Class /RPM/CL_DOC_COLL_PROXY_EDMS has no interface implemented.
Friends
Class /RPM/CL_DOC_COLL_PROXY_EDMS has no friend class.
Attributes
# | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
Instance attribute | Private | Object reference (TYPE REF TO) | IF_EDMS_DOCUMENT | EDMS: Document/Folder | 20080604 | ||
2 | ![]() |
Instance attribute | Private | Object reference (TYPE REF TO) | IF_EDMS_COMMON_FILE | CDOCS: Shared Interface for All File Types | 20080604 | ||
3 | ![]() |
Instance attribute | Private | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20080604 | ||
4 | ![]() |
Constant | Public | Type reference (TYPE) | EDMS_DOCID | 'root' | EDMS: Document ID | 20080604 |
Methods
Events
# | Event | Type | Visibility | Description | Created on |
---|---|---|---|---|---|
1 | CHANGED | Instance Event (0) |
Public (2) |
20080619 | |
2 | CREATED | Instance Event (0) |
Public (2) |
20080619 | |
3 | DELETED | Instance Event (0) |
Public (2) |
20080619 |
Types
Class /RPM/CL_DOC_COLL_PROXY_EDMS has no local type.
Method Signatures
Method CLASS_CONSTRUCTOR Signature
Method CLASS_CONSTRUCTOR on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Method CLASS_CONSTRUCTOR on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method CREATE_EDMS_PROXY_INSTANCE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IV_DOCID | Call by reference | Type reference (TYPE) | EDMS_DOCID | EDMS: Document ID | 20080604 | ||
2 | ![]() |
IV_PARENT_ID | Call by reference | Type reference (TYPE) | EDMS_DOCID | EDMS: Document ID | 20080604 | ||
3 | ![]() |
IV_WITH_CHILDREN | Call by reference | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20080604 |
Method CREATE_EDMS_PROXY_INSTANCE on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_ADMIN Signature
Method GET_ADMIN on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Method GET_ADMIN on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_ATTRIBUTES Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RT_FIELD_ATTRIBUTES | Value transfer | Type reference (TYPE) | DPR_TT_COLL_ATTRIBUTE | Table Type for Field Attributes | 20080604 |
Method GET_ATTRIBUTES on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_DEADLINE Signature
Method GET_DEADLINE on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Method GET_DEADLINE on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_DESCRIPTION Signature
Method GET_DESCRIPTION on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Method GET_DESCRIPTION on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_DESTINATION Signature
Method GET_DESTINATION on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Method GET_DESTINATION on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_EDMS_DOCUMENT Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RR_EDMS_DOCUMENT | Value transfer | Object reference (TYPE REF TO) | IF_EDMS_DOCUMENT | EDMS: Document/Folder | 20080604 |
Method GET_EDMS_DOCUMENT on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_FILE Signature
Method GET_FILE on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Method GET_FILE on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_LINKED_OBJECTS Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RT_LINKED_OBJECTS | Value transfer | Type reference (TYPE) | DPR_TT_COLL_LINKED_DPR_OBJECT | DPR Object Linked to CFX | 20080604 |
Method GET_LINKED_OBJECTS on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_NAME Signature
Method GET_NAME on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Method GET_NAME on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_OBJECT_TYPE Signature
Method GET_OBJECT_TYPE on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Method GET_OBJECT_TYPE on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method GET_STATUS_TEXT Signature
Method GET_STATUS_TEXT on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Method GET_STATUS_TEXT on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method IS_CHANGEABLE Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
RV_CHANGEABLE | Value transfer | Type reference (TYPE) | BOOLE_D | Data element for domain BOOLE: TRUE (='X') and FALSE (=' ') | 20080604 |
Method IS_CHANGEABLE on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method MOVE_CHILDREN Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IS_TARGET | Call by reference | Type reference (TYPE) | SIBFLPORB | Local Persistent Object Reference - BOR Compatible | 20080604 | ||
2 | ![]() |
IT_CHILDREN | Call by reference | Type reference (TYPE) | EDMS_TT_DOCUMENT_ID | EDMS: List of Documents | 20080604 | ||
3 | ![]() |
IV_TARGET_FOLDER | Call by reference | Type reference (TYPE) | EDMS_DOCID | EDMS: Document ID | 20080604 |
Method MOVE_CHILDREN on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method ON_EDMS_API_COPIED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IS_EDMS_LINK_TARGET | Call by reference | Type reference (TYPE) | SIBFLPORB | Local Persistent Object Reference - BOR Compatible | 20080604 | ||
2 | ![]() |
IT_DOCUMENTS | Call by reference | Type reference (TYPE) | EDMS_TT_DOCID | EDMS: List of Document IDs | 20080604 | ||
3 | ![]() |
I_COPIED | Call by reference | Type reference (TYPE) | ABAP_BOOL | 20080604 | |||
4 | ![]() |
I_SOURCE_FOLDER | Call by reference | Type reference (TYPE) | EDMS_DOCID | EDMS: Document ID | 20080604 | ||
5 | ![]() |
I_TARGET_FOLDER | Call by reference | Type reference (TYPE) | EDMS_DOCID | EDMS: Document ID | 20080604 |
Method ON_EDMS_API_COPIED on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method ON_EDMS_CHANGED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
I_DOCID | Value transfer | Attribute reference (LIKE) | 20080604 |
Method ON_EDMS_CHANGED on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method ON_EDMS_DELETED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
SENDER | Value transfer | Attribute reference (LIKE) | 20080604 |
Method ON_EDMS_DELETED on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Method ON_EDMS_MOVED Signature
# | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
---|---|---|---|---|---|---|---|---|---|
1 | ![]() |
IS_TARGET | Call by reference | Type reference (TYPE) | SIBFLPORB | Local Persistent Object Reference - BOR Compatible | 20080604 | ||
2 | ![]() |
IV_SOURCE_FOLDER | Call by reference | Type reference (TYPE) | EDMS_DOCID | EDMS: Document ID | 20080604 | ||
3 | ![]() |
IV_TARGET_FOLDER | Call by reference | Type reference (TYPE) | EDMS_DOCID | EDMS: Document ID | 20080604 |
Method ON_EDMS_MOVED on class /RPM/CL_DOC_COLL_PROXY_EDMS has no exception.
Event Signatures
Event CHANGED Signature
Event CHANGED on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Event CREATED Signature
Event CREATED on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
Event DELETED Signature
Event DELETED on class /RPM/CL_DOC_COLL_PROXY_EDMS has no parameter.
History
Last changed by/on | SAP | 20141109 |
SAP Release Created in | 500_701 |