SAP ABAP Class /PLMU/IF_FRW_MAP (Mapping)
Meta Relationship - Using
# Relationship type Using Short Description Created on
1 Interface composition (i COMPRISING i_ref)  /PLMB/IF_FRW_MAP Generic Mapping 20080612
Meta Relationship - Used By
# Relationship type Used by Short Description Created on
1 Interface implementation (CLASS c. INTERFACES i_ref)  /PLMU/CL_FRW_MAP Mapping 20080612
Properties
Class /PLMU/IF_FRW_MAP  
Short Description Mapping    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package      
Created 20080611   SAP 
Last change 20110908   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
Class /PLMU/IF_FRW_MAP has no forward declaration.
Interfaces
Class /PLMU/IF_FRW_MAP has no interface implemented.
Friends
Class /PLMU/IF_FRW_MAP has no friend class.
Attributes
Class /PLMU/IF_FRW_MAP has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 CONVERT_CE_TO_STRUCTURE Static method Public Method Convert Context Element to Structure 20080618
2 CONVERT_STRUCTURE_TO_CE Static method Public Method Convert Structure to Context Element 20080618
3 GET_OBJECT_TYPE Instance method Public Method 20080612
4 GET_OBJECT_TYPE_CE Instance method Public Method Get object type of WD context element attribute 20080612
5 MAP_FROM_CE Instance method Public Method Map from WD context element to parameters 20080612
6 MAP_FROM_STRUCTURE Instance method Public Method 20080612
7 MAP_FROM_TABLE Instance method Public Method 20091118
8 MAP_TO_CE Instance method Public Method Map from parameters to WD context element 20080612
9 MAP_TO_STRUCTURE Instance method Public Method 20080612
10 MAP_TO_TABLE Instance method Public Method 20091118
Events
Class /PLMU/IF_FRW_MAP has no event.
Types
Class /PLMU/IF_FRW_MAP has no local type.
Method Signatures

Method CONVERT_CE_TO_STRUCTURE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ER_STRUCTURE Call by reference Object reference (TYPE REF TO) DATA Structure reference 20080618
2 Importing IO_CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Interface for Node Element 20080618

Method CONVERT_CE_TO_STRUCTURE on class /PLMU/IF_FRW_MAP has no exception.

Method CONVERT_STRUCTURE_TO_CE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CO_CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Interface for Node Element 20080618
2 Importing IS_STRUCTURE Call by reference Type reference (TYPE) DATA 20080618

Method CONVERT_STRUCTURE_TO_CE on class /PLMU/IF_FRW_MAP has no exception.

Method GET_OBJECT_TYPE Signature

Method GET_OBJECT_TYPE on class /PLMU/IF_FRW_MAP has no parameter.
Method GET_OBJECT_TYPE on class /PLMU/IF_FRW_MAP has no exception.

Method GET_OBJECT_TYPE_CE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting EV_OTYPE Call by reference Type reference (TYPE) /PLMB/GOS_OBJECT_TYPE Object Type 20080618
2 Importing IO_CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Interface for Node Element 20080618
3 Importing IV_FIELD_NAME Call by reference Type reference (TYPE) FIELDNAME Field Name 20080618
# Exception Resumable Description Created on
1 /PLMB/CX_FRW_NO_OTYPE No Object Type could be retrieved 20080723

Method MAP_FROM_CE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CT_PARAMETERS Call by reference Type reference (TYPE) /PLMB/T_FRW_PARAMETERS Parameters 20080618
2 Importing IO_CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Interface for Node Element 20080618
3 Importing IV_FIELD_NAME Call by reference Type reference (TYPE) FIELDNAME Field Name 20080618
# Exception Resumable Description Created on
1 /PLMB/CX_FRW_MAPPING Mapping Error 20090604

Method MAP_FROM_STRUCTURE Signature

Method MAP_FROM_STRUCTURE on class /PLMU/IF_FRW_MAP has no parameter.
Method MAP_FROM_STRUCTURE on class /PLMU/IF_FRW_MAP has no exception.

Method MAP_FROM_TABLE Signature

Method MAP_FROM_TABLE on class /PLMU/IF_FRW_MAP has no parameter.
Method MAP_FROM_TABLE on class /PLMU/IF_FRW_MAP has no exception.

Method MAP_TO_CE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CO_CONTEXT_ELEMENT Call by reference Object reference (TYPE REF TO) IF_WD_CONTEXT_ELEMENT Web Dynpro: Interface for Node Element 20080618
2 Importing IT_PARAMETERS Call by reference Type reference (TYPE) /PLMB/T_FRW_PARAMETERS Parameters 20080618
# Exception Resumable Description Created on
1 /PLMB/CX_FRW_MAPPING Mapping Error 20090604

Method MAP_TO_STRUCTURE Signature

Method MAP_TO_STRUCTURE on class /PLMU/IF_FRW_MAP has no parameter.
Method MAP_TO_STRUCTURE on class /PLMU/IF_FRW_MAP has no exception.

Method MAP_TO_TABLE Signature

Method MAP_TO_TABLE on class /PLMU/IF_FRW_MAP has no parameter.
Method MAP_TO_TABLE on class /PLMU/IF_FRW_MAP has no exception.
History
Last changed by/on SAP  20110908 
SAP Release Created in