SAP ABAP Class /EACC/CL_PRNTA_CONFIGURATOR (Source Document Configurator)
Hierarchy
☛
SEM-BW (Software Component) SEM-BW: Strategic Enterprise Management
⤷
FIN-BAC-GL (Application Component) General Ledger
⤷
/EACC/PRIMANOTA (Package) Source Document Tool
⤷
⤷
Meta Relationship - Using
| # | Relationship type | Using | Short Description | Created on |
|---|---|---|---|---|
| 1 | Interface implementation (CLASS c. INTERFACES i_ref) | IF_FINB_GN_BUILDING_PLAN | Blueprint for Generating Raw Objects | 20020510 |
Properties
| Class | /EACC/CL_PRNTA_CONFIGURATOR | |
| Short Description | Source Document Configurator | |
| Super Class | ||
| Instantiability of a Class | 2 | Public |
| Final |
General Data
| Message Class | ||
| Program status | ||
| Category | 0 | |
| Package | /EACC/PRIMANOTA | Source Document Tool |
| Created | 20020430 | SAP |
| Last change | 20041209 | SAP |
| Shared Memory-enabled | ||
| Fixed point arithmetic | ||
| Unicode checks active |
Forward declarations
| # | Type group / Object type | Type | Type Description |
|---|---|---|---|
| 1 | Forward declaration class (CLASS c DEFINITION DEFERRED) | Forward declaration class (CLASS c DEFINITION DEFERRED) |
Interfaces
| # | Interface | Abstract | Final | Description | Created on |
|---|---|---|---|---|---|
| 1 | IF_FINB_GN_BUILDING_PLAN | Blueprint for Generating Raw Objects | 20020510 |
Friends
Class /EACC/CL_PRNTA_CONFIGURATOR has no friend class.
Attributes
| # | Attribute | Level | Visibility | Read only | Typing | Associated Type | Initial Value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Instance attribute | Private | Object reference (TYPE REF TO) | IF_FINB_GN_LOW_LEVEL | Low Level Interface of Generator | 20020503 | |||
| 2 | Instance attribute | Public | Type reference (TYPE) | FINB_KF_CHARS | Characteristics and Key Figures | 20021011 | |||
| 3 | Instance attribute | Private | Type reference (TYPE) | FINB_MD_APPLICATION | FIN Master Data: Application | 20020513 | |||
| 4 | Instance attribute | Private | Type reference (TYPE) | FINB_MD_REGID | FIN Master Data: Application Area | 20020617 | |||
| 5 | Instance attribute | Private | Type reference (TYPE) | ACC_DATABASIS | Data Basis | 20020617 | |||
| 6 | Static Attribute | Public | Type reference (TYPE) | CHAR50 | '/EACC/CL_PRNTA_CONFIGURATOR' | Blueprint Name | 20020513 |
Methods
| # | Method | Level | Visibility | Method type | Description | Created on |
|---|---|---|---|---|---|---|
| 1 | Instance method | Public | Method | Configurator | 20020430 | |
| 2 | Instance method | Public | Constructor | 20020430 | ||
| 3 | Instance method | Public | Method | Create number range intervals | 20020731 | |
| 4 | Static method | Public | Method | Provides Technical Source Document Fields To Be Registered | 20020716 | |
| 5 | Instance method | Public | Method | Configures Reporting Tool | 20020807 |
Events
Class /EACC/CL_PRNTA_CONFIGURATOR has no event.
Types
Class /EACC/CL_PRNTA_CONFIGURATOR has no local type.
Method Signatures
Method CONFIGURATOR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IR_PN_CONFIG | Call by reference | Object reference (TYPE REF TO) | /EACC/IF_PN_CONFIGURATION | Konfiguration Prima Nota | 20020430 | |||
| 2 | PATTERN_CONFIG_ID | Call by reference | Type reference (TYPE) | /EACC/CONFIG_ID | Konfigurations-ID | 20020614 | |||
| 3 | PRNTA_CONFIG_ID | Call by reference | Type reference (TYPE) | /EACC/CONFIG_ID | Konfigurations-ID | 20020614 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Feldname ungültig | 20040628 |
Method CONSTRUCTOR Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | I_APPLICATION | Value transfer | Type reference (TYPE) | FINB_MD_APPLICATION | FI-Stammdaten: Anwendung | 20020510 | |||
| 2 | I_CONFIG_KEY | Value transfer | Type reference (TYPE) | CLIKE | 20020510 | ||||
| 3 | I_CONFIG_KEY_EXTENSION | Call by reference | Type reference (TYPE) | CLIKE | 20020510 | ||||
| 4 | I_CONFIG_OBJ | Value transfer | Type reference (TYPE) | CLIKE | 20020510 | ||||
| 5 | I_ON_DELETE | Call by reference | Type reference (TYPE) | BOOLE_D | CL_FINB_CONS_GENERATOR=>A_FALSE | Datenelement zur Domäne BOOLE: TRUE (='X') und FALSE (=' ') | 20020510 |
Method CONSTRUCTOR on class /EACC/CL_PRNTA_CONFIGURATOR has no exception.
Method CREATE_NUMBER_RANGE_INTERVALS Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | IO_PNTA_CONFIG | Call by reference | Object reference (TYPE REF TO) | /EACC/IF_PN_CONFIGURATION | Konfiguration Prima Nota | 20020807 | |||
| 2 | I_NR_OBJECT | Call by reference | Type reference (TYPE) | TNRO-OBJECT | Nummerkreis Objekt | 20020807 |
| # | Exception | Resumable | Description | Created on |
|---|---|---|---|---|
| 1 | Intervalle wurden schon angelegt | 20020731 | ||
| 2 | Nummernkreisobjekt ist nicht gefunden | 20020731 | ||
| 3 | Subobjekt ist nicht definiert | 20020731 |
Method GET_CHARS_TO_BE_REGISTERED Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | ET_KFCHAR_REG | Call by reference | Type reference (TYPE) | ACC_T_KFCHAR_REG | Merkmalsregistierungsinformation | 20020716 |
Method GET_CHARS_TO_BE_REGISTERED on class /EACC/CL_PRNTA_CONFIGURATOR has no exception.
Method GET_REPORTING_HANDLE Signature
| # | Type | Parameter | Pass Value | Optional | Typing Method | Associated Type | Default value | Description | Created on |
|---|---|---|---|---|---|---|---|---|---|
| 1 | E_REPORTING_HANDLE | Value transfer | Type reference (TYPE) | /EACC/CONFIG_ID | Reporting Konfigurations-ID | 20020807 | |||
| 2 | I_CONFIG_ID | Call by reference | Type reference (TYPE) | /EACC/CONFIG_ID | Plima Konfigurations- ID | 20020807 | |||
| 3 | I_READ_FORMAT | Call by reference | Type reference (TYPE) | /EACC/LINE_ITEM_READ_FORMAT | Einzelpostenleseformat | 20020807 |
Method GET_REPORTING_HANDLE on class /EACC/CL_PRNTA_CONFIGURATOR has no exception.
History
| Last changed by/on | SAP | 20041209 |
| SAP Release Created in | 10B |