Data Element | NZAEHC |
Short Description | Next/Last Planned Counter Reading |
Data Type
Category of Dictionary Type | D | Domain |
Type of Object Referenced | No Information | |
Domain / Name of Reference Type | WZYKL | |
Data Type | CHAR | Character String |
Length | 22 | |
Decimal Places | 0 | |
Output Length | 22 | |
Value Table |
Further Characteristics
Search Help: Name | ||
Search Help: Parameters | ||
Parameter ID | ||
Default Component name | ||
Change document | ||
No Input History | ||
Basic direction is set to LTR | ||
No BIDI Filtering |
Field Label
Length | Field Label | |
Short | 10 | NxtCtrRdg |
Medium | 15 | NxtCountReadg |
Long | 20 | NxtPlanCountReading |
Heading | 15 | NxtCountReadg |
Documentation
Definition
The counter reading at which the next>/> maintenance task, for example, a maintenance order is due.
In the couter history, the field can also have the following meaning:
The system displays the counter reading at which the last maintenance task was due.
Supplementary Documentation - NZAEHC 0001
Use
In a performance-based maintenance plan, the planned counter reading is calculated automatically by the system on scheduling.
Example
Package due: every 5,000 miles
Total counter
reading: 12,300 miles
Next planned
counter reading: 17,300 miles
Supplementary Documentation - NZAEHC 0002
Procedure
If you want to maintain the planned counter reading manually, enter a counter reading in this field.
Example
A pump's counter is reactivated in the preventive maintenance plan after unexpected repairs have been carried out.
The total counter reading is 82,150 liters. A maintenance task is due every 10,000 liters. As the pump has just been repaired outside the normal maintenance cycle, the next task is not to take place at 92,150 liters, but at 100,000 liters instead.
Package due: every 10,000 L
Total counter reading: 82,150 L
Next theoretical
planned counter reading: 92,150 L
Counter reading
maintained manually: 100,000 L
Supplementary Documentation - NZAEHC 0003
Use
In the case of a multiple counter plan, you can either maintain the planned counter reading manually or have the system calculate it on scheduling.
Procedure
If you want to maintain the planned counter reading manually, call up the function for maintaining a planned counter reading in the change mode, and enter a counter reading in the field NxtPlanCountReading.
Example
A pump's counter is reactivated in the maintenance plan after unexpected repairs have been carried out.
The total counter reading is 82,150 liters. A maintenance task is due every 10,000 liters. As the pump has just been repaired outside the normal maintenance cycle, the next task is not to take place at 92,500 liters, but at 100,000 liters instead.
Package due: every 10,000 L
Total counter reading: 82,150 L
Next theoretical
planned counter reading: 92,150 L
Counter reading
maintained manually: 100,000 L