Basic Data
Data Element GW_SAPRC
Short Description SAP Gateway and CPIC Return Code  
Data Type
Category of Dictionary Type D   Domain
Type of Object Referenced     No Information
Domain / Name of Reference Type INT2    
Data Type INT2   2-byte integer, only for length field before LCHR or LRAW 
Length 5    
Decimal Places 0    
Output Length 5    
Value Table      
Further Characteristics
Search Help: Name    
Search Help: Parameters    
Parameter ID   
Default Component name    
Change document    
No Input History    
Basic direction is set to LTR    
No BIDI Filtering    
Field Label
  Length  Field Label  
Short SAP RC 
Medium 16 SAP Return Code 
Long 16 SAP Return Code 
Heading 16 SAP Return Code 
Documentation

Definition

These return values are defined by SAP.

The previous and following syslog messages provide further details on the source of the error.

If you require additional information, you must analyze the trace files that are affected.

You can find all CIPC and gateway error codes in SAP Note 63347.


0 OK
221 General CPIC error
222 No memory available
223 Network read error
224 Network write error
225 Invalid request
226 No connection with the system
227 Gateway process ended
228 Memory area read error
229 Memory area write error
230 No available LU
231 No available gateway process
232 Error when starting gateway process
233 Incorrect communication type
234 Connection setup failed
235 Error when processing connection table
236 No connection to gateway
237 Connection to gateway terminated
238 Write error with gateway
239 Read error with gateway
240 Invalid length
241 Invalid environment
242 Timeout when setting up connection
243 Error when setting up local system connection
244 Error when setting up local system connection
245 Memory overflow
246 Invalid header version
247 Gateway not started
248 Error when accessing table TXCOM
249 Communication table full
630 Invalid mode
631 Max. number of gateways reached
632 No LU entered
633 Max. number of CPIC clients reached
634 Invalid TP name
635 Failed to start a local program
636 Invalid network handle
637 Failed to start remote program
638 Failed to start program
639 Failed to send datagram
640 Internal gateway error
664 Gateway host unknown
665 Gateway service name unknown
666 Gateway network error
667 Failed to execute command
668 The R/2 System was restarted
669 Symbolic definition too long
670 No further side info entries
672 Logon failed
673 IMS error purging
674 Terminal output
676 Gateway security error
677 Timeout for registered program
678 Program is registered
679 Program is not registered
720 Program must not be registered
721 SNC is deactivated
722 SNC is urgently required
723 SNC name not set
724 No standard SNC name exists
725 Log does not support SNC
726 Gateway not connected to system
727 SNC is not required for this connection
728 Conversation ID not found
729 Insecure communication via the security port
730 Start of insecure programs not permitted
731 Gateway was shut down
732 Start of remote programs not permitted

The following return values are returned to the gateway by the CPIC library or are output in the trace file.

450 No memory available
451 No side info found
452 Error in SNA function (TP_START)
453 No initialization
454 Error in SNA function (GETLU)
455 Program received a signal
456 Timeout when setting up connection
457 Error in SNA function (ALLC)
458 Error in SNA function (SEND)
459 Error in SNA function (PREPARE)
460 Error in SNA functionn (FLUSH)
461 SNA function error ( RECEIVE )
462 Missing command line argument
463 SNA function error (GET_ALLOCATE)
464 SNA function error (DEAL)
465 SNA function error (TP_END)
466 Maximum number of connections reached
467 SNA function error (SNAOPEN)
468 SNA function error (SNACTL)
469 FLUSH not supported
470 SNA function error (SNACLSE)
471 Incorrect connection status
472 No entry in side info found
473 No connection found
474 Connection terminated manually
475 Connection terminated automatically
476 No connection partner found
477 SNA function error (CONFIRM)
478 SNA function error (CONFIRMED)
479 Host entry not in side info
480 Service entry not in side info
481 Protocol entry not in side info
482 LU entry not in side info
483 TP entry not in side info
484 No connection to gateway
485 Errors in function gethostname
486 SAP_CMACCP not executed
487 Name not in argument list
488 Host not in argument list
489 Service not in argument list
490 Conv ID not in argument list
491 Invalid call parameter
492 LU62CVCT failed
493 LU62ATTACH failed )
494 No conv table found
495 Incorrect conv table
496 Incorrect conv table entries
497 NiHostToAddr error
498 NiAddrToHost error
499 Error accessing table THOST
760 Gateway failed to find side info file
761 SNA function error ( RECEIVE )
762 SNC_LIB not in argument list
763 SNC not in argument list
764 Invalid SNC handle
765 SNC deactivated
766 SNC error
767 SNC_MODE=ON , SNC required
768 SNC not available
769 Invalid call parameter
770 Memory area too small
771 SNC: invalid status
772 CPIC and SAP return values
773 Invalid registration status to execute the function
774 Output of CPIC and SAP return codes
775 No symbolic destination available

History
Last changed by/on SAP  20140117 
SAP Release Created in 740