SAP ABAP Class CL_RSINSP_INSP_DB (Database Accesses for Inspection Plans)
Hierarchy
SAP_BW (Software Component) SAP Business Warehouse
   BW-WHM-DST (Application Component) Data Staging
     RSIQM_INSPECTION (Package) IQM in BI: Inspection Plan
Properties
Class CL_RSINSP_INSP_DB  
Short Description Database Accesses for Inspection Plans    
Super Class    
Instantiability of a Class 2  Public 
Final    
General Data
Message Class    
Program status     
Category 0   
Package RSIQM_INSPECTION   IQM in BI: Inspection Plan 
Created 20060511   SAP 
Last change 20130531   SAP 
Shared Memory-enabled    
Fixed point arithmetic    
Unicode checks active    
Forward declarations
# Type group / Object type Type Type Description
1 RS Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
2 RSIPC Type group use (TYPE-POOLS tp)  Type group use (TYPE-POOLS tp)
Interfaces
Class CL_RSINSP_INSP_DB has no interface implemented.
Friends
Class CL_RSINSP_INSP_DB has no friend class.
Attributes
Class CL_RSINSP_INSP_DB has no attribute.
Methods
# Method Level Visibility Method type Description Created on
1 DELETE Static method Public Method Delete Inspection Plan 20060511
2 EXISTS Static method Public Method Does the Inspection Plan Exist? 20060511
3 GET_BY_INFOAREA Static method Public Method Inspection Plans of an InfoArea 20060818
4 SAVE Static method Public Method Save Inspection Plan 20060511
5 SELECT Static method Public Method Read Inspection Plan 20060511
6 SELECT_ALL_INSPT_BY_LANGU Static method Public Method Read all Texts for Inspection Plan 20060517
7 SELECT_ALL_INSP_BY_VERSION Static method Public Method Select all Header Data by Version 20060517
8 SELECT_INSPCHECK_BY_NAME Static method Public Method Selection by Checking Name 20061113
9 UPDATE_INFOAREA Static method Public Method Refresh InfoArea 20060821
10 UPDATE_OBJSTAT Static method Public Method Update Object Status 20060511
11 UPDATE_TIMESTAMP Static method Public Method Update Timestamp 20060511
12 _CHECK_OBJVERS Static method Private Method Check of Object Version 20060511
13 _DELETE_DB Static method Private Method Delete on the Database 20060511
14 _GET_DELTATIME Static method Private Method Output Delta Time 20060705
15 _INSERT_DB Static method Private Method Save on the Database 20060511
16 _IS_OBJVERS Static method Private Method Check of Object Version 20060519
17 _SELECT_INSP Static method Private Method Read Header Data 20060511
Events
Class CL_RSINSP_INSP_DB has no event.
Types
Class CL_RSINSP_INSP_DB has no local type.
Method Signatures

Method DELETE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_INSPECTION Call by reference Type reference (TYPE) RSINSP_INSPECTION Inspektionsplan 20060511
2 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060511
# Exception Resumable Description Created on
1 FAILED Löschen fehlgeschlagen 20060511

Method EXISTS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_INSPECTION Call by reference Type reference (TYPE) RSINSP_INSPECTION Inspektionsplan 20060511
2 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060511
3 Returning RV_EXISTS Value transfer Type reference (TYPE) RS_BOOL Boolean 20060511

Method EXISTS on class CL_RSINSP_INSP_DB has no exception.

Method GET_BY_INFOAREA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_INSPECTION Call by reference Type reference (TYPE) RSINSP_INSPECTION_T Inspektionspläne 20060818
2 Importing IV_INFOAREA Call by reference Type reference (TYPE) RSINFOAREA InfoArea 20060818
3 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060818

Method GET_BY_INFOAREA on class CL_RSINSP_INSP_DB has no exception.

Method SAVE Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_INSP Call by reference Type reference (TYPE) RSINSP Inspektionsplan 20060511
2 Importing IT_INSPCHECK Call by reference Type reference (TYPE) RSINSP_INSPCHECK_T Tabelle mit Prüfungen in Inspektionsplänen 20060511
3 Importing IT_INSPCHECKT Call by reference Type reference (TYPE) RSINSP_INSPCHECKT_T Tabelle Texten zu Prüfungen in Inspektionsplänen 20060511
4 Importing IT_INSPSRC Call by reference Type reference (TYPE) RSINSP_INSPSRC_T Quellobjekte in Inspektionsplänen 20060921
5 Importing IT_INSPT Call by reference Type reference (TYPE) RSINSP_INSPT_T Tabelle mit Texten zu Inspektionsplänen 20060511
# Exception Resumable Description Created on
1 FAILED Sichern fehlgeschlagen 20060511

Method SELECT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_INSP Call by reference Type reference (TYPE) RSINSP Inspektionsplan 20060511
2 Exporting ET_INSPCHECK Call by reference Type reference (TYPE) RSINSP_INSPCHECK_T Tabelle mit Prüfungen in Inspektionsplänen 20060511
3 Exporting ET_INSPCHECKT Call by reference Type reference (TYPE) RSINSP_INSPCHECKT_T Tabelle Texten zu Prüfungen in Inspektionsplänen 20060511
4 Exporting ET_INSPSRC Call by reference Type reference (TYPE) RSINSP_INSPSRC_T Quellobjekte in Inspektionsplänen 20060921
5 Exporting ET_INSPT Call by reference Type reference (TYPE) RSINSP_INSPT_T Tabelle mit Texten zu Inspektionsplänen 20060511
6 Importing IV_ALL_LANGU Call by reference Type reference (TYPE) RS_BOOL RS_C_FALSE alle Sprachen ausgeben 20060516
7 Importing IV_INSPECTION Call by reference Type reference (TYPE) RSINSP_INSPECTION Inspektionsplan 20060511
8 Importing IV_LANGU Call by reference Type reference (TYPE) SY-LANGU SY-LANGU Sprachenschlüssel der aktuellen Textumgebung 20060511
9 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060511
# Exception Resumable Description Created on
1 NOT_FOUND existiert nicht auf der Datenbank 20060511

Method SELECT_ALL_INSPT_BY_LANGU Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_INSPT Call by reference Type reference (TYPE) RSINSP_INSPT_T Tabelle mit Texten zu Inspektionsplänen 20060517
2 Importing IT_INSP Call by reference Type reference (TYPE) RSINSP_INSP_T Tabelle mit Inspektionsplänen 20060517
3 Importing IV_LANGU Call by reference Type reference (TYPE) SY-LANGU Sprachenschlüssel der aktuellen Textumgebung 20060517

Method SELECT_ALL_INSPT_BY_LANGU on class CL_RSINSP_INSP_DB has no exception.

Method SELECT_ALL_INSP_BY_VERSION Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_INSP Call by reference Type reference (TYPE) RSINSP_INSP_T Tabelle mit Inspektionsplänen 20060517
2 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060517

Method SELECT_ALL_INSP_BY_VERSION on class CL_RSINSP_INSP_DB has no exception.

Method SELECT_INSPCHECK_BY_NAME Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ET_INSPCHECK Call by reference Type reference (TYPE) RSINSP_INSPCHECK_T Prüfungen in Inspektionsplänen 20061113
2 Exporting ET_INSPCHECKT Call by reference Type reference (TYPE) RSINSP_INSPCHECKT_T Texten zu Prüfungen 20061113
3 Importing IT_CHECK Call by reference Type reference (TYPE) RSINSP_CHECK_T Prüfungen 20061113
4 Importing IV_INSPECTION_EXCL Call by reference Type reference (TYPE) RSINSP_INSPECTION Inspektionsplan 20061113
5 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20061113

Method SELECT_INSPCHECK_BY_NAME on class CL_RSINSP_INSP_DB has no exception.

Method UPDATE_INFOAREA Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_INFOAREA Call by reference Type reference (TYPE) RSINFOAREA InfoArea 20060821
2 Importing IV_INSPECTION Call by reference Type reference (TYPE) RSINSP_INSPECTION Inspektionsplan 20060821
3 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060821
# Exception Resumable Description Created on
1 FAILED fehlgeschlagen 20060908

Method UPDATE_OBJSTAT Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_INSPECTION Call by reference Type reference (TYPE) RSINSP_INSPECTION Inspektionsplan 20060511
2 Importing IV_OBJSTAT Call by reference Type reference (TYPE) RSOBJSTAT Objektstatus 20060511
3 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060511
# Exception Resumable Description Created on
1 FAILED fehlgeschlagen 20060908

Method UPDATE_TIMESTAMP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_INSPECTION Call by reference Type reference (TYPE) RSINSP_INSPECTION Inspektionsplan 20060511
2 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060511
3 Importing IV_TIMESTMP Call by reference Type reference (TYPE) RSTIMESTMP UTC-Zeitstempel in Kurzform (JJJJMMTThhmmss) 20060511
4 Importing IV_TSTPNM Call by reference Type reference (TYPE) RSTSTPNM Letzter Änderer 20060511
# Exception Resumable Description Created on
1 FAILED fehlgeschlagen 20060908

Method _CHECK_OBJVERS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060511

Method _CHECK_OBJVERS on class CL_RSINSP_INSP_DB has no exception.

Method _DELETE_DB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_INSPECTION Call by reference Type reference (TYPE) RSINSP_INSPECTION Inspektionsplan 20060511
2 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060511

Method _DELETE_DB on class CL_RSINSP_INSP_DB has no exception.

Method _GET_DELTATIME Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Returning RV_DELTATIME Value transfer Type reference (TYPE) SIQM_DELTATIME LOC-Zeitstempel in Kurzform (JJJJMMTThhmmss) für BI-Delta 20060705

Method _GET_DELTATIME on class CL_RSINSP_INSP_DB has no exception.

Method _INSERT_DB Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Changing CS_INSP Call by reference Type reference (TYPE) RSINSP Inspektionsplan 20060511
2 Importing IT_INSPCHECK Call by reference Type reference (TYPE) RSINSP_INSPCHECK_T Tabelle mit Prüfungen in Inspektionsplänen 20060511
3 Importing IT_INSPCHECKT Call by reference Type reference (TYPE) RSINSP_INSPCHECKT_T Tabelle Texten zu Prüfungen in Inspektionsplänen 20060511
4 Importing IT_INSPSRC Call by reference Type reference (TYPE) RSINSP_INSPSRC_T Quellobjekte in Inspektionsplänen 20060921
5 Importing IT_INSPT Call by reference Type reference (TYPE) RSINSP_INSPT_T Tabelle mit Texten zu Inspektionsplänen 20060511
# Exception Resumable Description Created on
1 FAILED Speichern fehlgeschlagen 20060511

Method _IS_OBJVERS Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060519
2 Returning RV_SUPPORTED Value transfer Type reference (TYPE) RS_BOOL Boolean 20060519

Method _IS_OBJVERS on class CL_RSINSP_INSP_DB has no exception.

Method _SELECT_INSP Signature

# Type Parameter Pass Value Optional Typing Method Associated Type Default value Description Created on
1 Exporting ES_INSP Call by reference Type reference (TYPE) RSINSP Inspektionsplan 20060511
2 Importing IV_INSPECTION Call by reference Type reference (TYPE) RSINSP_INSPECTION Inspektionsplan 20060511
3 Importing IV_OBJVERS Call by reference Type reference (TYPE) RSOBJVERS Objektversion 20060511
# Exception Resumable Description Created on
1 NOT_FOUND existiert nicht auf der Datenbank 20060511
History
Last changed by/on SAP  20130531 
SAP Release Created in 710